12: If time is (P92)

1: 0

minutes into interval

2: 60

minute interval

3: 10

Set high Flag 0(output)

13: Sample (P70)

1: 2

Reps

2: 1

Loc [TempC]

When the program is executed, the datalogger will perform the Sample (P70)

instruction twice. The first time, it will sample the value stored in the TempC

location. The second time, it will sample the value stored in the BatteryV

location.

If an Input Location is inserted between the TempC and BatteryV

location, the inserted location will be sampled instead of BatteryV.

7.4.9 Input Location Editor

Input Location labels can be entered and edited by using the Input Location

Editor. To access the Input Location Editor, select Edit | Input Labels or press

<F5>.

NOTE

7-69