Section 6. Network Status and Resolving Communication Problems

Memory Code (Mem Code) (Array-based dataloggers only) This

number is an indication of the amount of memory available in the

datalogger. The amount of memory represented depends on the

datalogger. See the datalogger operator’s manual for more information.

Next Data Collection (Next Data Coll) – The date and time of the next

scheduled data collection for the device.

Polling Active – True indicates that LoggerNet is currently receiving data

for this device.

Program Overrun (Prog Overrun) – (Array-based dataloggers only)

This is the number of table overruns recorded for the running datalogger

program. This is the same number available from *B mode with keyboard

displays or through the terminal mode.

RFTD Blacklisted – Indicates that a station has been blacklisted by the

RF Base following a failed communication attempt. The RF Base will not

forward communication attempts originating from LoggerNet to a

blacklisted station. This includes clock checks, getting table definitions,

data collection, program sends, etc. However, the RF Base will continue to

request communications with the blacklisted station on its regular RF

Polling Interval. Once the station has responded to one of these regular RF

polling broadcasts, it will be removed from the blacklist. At that point,

communication attempts originating from LoggerNet will be allowed

again.

Table Defs State – Indicates the status of the datalogger’s table

definitions, as known by the LoggerNet server.

None – No table definitions have been retrieved from the datalogger.

Current – The table definitions from the datalogger match what LoggerNet

has stored as the table definitions for the datalogger.

Suspect – A collection attempt has returned an invalid table definitions

code. LoggerNet will attempt to verify the table definitions for the

datalogger.

Getting Table Defs – LoggerNet is in the process of retrieving the table

definitions from the datalogger.

Invalid Table Defs – The table definitions from the datalogger do not

match what LoggerNet has stored as the table definitions for the

datalogger. Table definitions will need to be updated before data

collection can occur.

Total Attempts – The total number of communication attempts with the

device since LoggerNet was started or retries were reset.

Total Failures – The total number of communication attempts with the

device that have failed since LoggerNet was started or retries were reset.

6-7