2 display/subnet, 3 toggle collection on/off, 4 reset device – Campbell Scientific LoggerNet Datalogger Support Software User Manual

Page 198: 5 collect now/stop collection, Display/subnet -8, Toggle collection on/off -8, Reset device -8, Collect now/stop collection -8

Advertising
background image

Section 6. Network Status and Resolving Communication Problems

Total Retries – The total number of communication attempts with a

device after the original attempt failed since LoggerNet was started or

retries were reset.

Uncoll Holes – The number of values in holes that cannot be collected

from the datalogger (most often, because the data has been overwritten by

newer data).

Values In Last Collect (Vals Last Collect) – The number of values that

were collected during the last data collection attempt. Used in

combination with the Values to Collect the user can get an idea of how

much data is left to collect.

Values to Collect (Vals to Collect) – The total number of values to be

collected. When LoggerNet first contacts the datalogger it finds out how

many data values are waiting to be collected.

Watchdog Error (Watchdog Err) – (Array-based dataloggers only) This

is the number of Watchdog Errors being reported by the datalogger. This

is the same number that is available from *B mode with keyboard displays

or using the remote keyboard. See the datalogger operator’s manual for

more information.

6.1.2.2 Display/Subnet

The Display button can be used to determine what is shown in your network

map. You can choose to view only your dataloggers by selecting

Stations

Only. Selecting All Devices will show your entire network including root

devices, communication devices, etc.

In LoggerNet Admin, you can also use the Subnet button to view a subnet of

your network map. Subnets are configured from the Setup Screen’s View |

Configure Subnets menu item.

6.1.2.3 Toggle Collection On/Off

Pressing the Toggle On/Off button toggles scheduled collection on or off for

the selected datalogger. The change to scheduled collection is reflected on the

Setup Screen for this datalogger. The function is only enabled when a

datalogger is selected in the network map. Collection can also be toggled by

selecting Toggle On/Off from the right-click menu.

6.1.2.4 Reset Device

Resets the collection state and error statistics for the selected device. Reset

Device is done either from the button or selecting Reset Device from the right-

click menu.

6.1.2.5 Collect Now/Stop Collection

Collect Now starts data collection for the selected datalogger. This is the

equivalent of the Collect Now button on the Connect Screen. Data collection

will use the file settings from the Data Files or Final Storage Area 1 or 2 tabs

on the Setup Screen. While data collection is in progress, pressing Stop

Collection will stop the collection. This might be needed if the datalogger has

6-8

Advertising