Section 7. Creating and Editing Datalogger Programs

controls are off when a datalogger powers up so as to make the control decision

based on a fresh measurement. See the datalogger manual for a full description

of this feature.

7.2.3.4 Select CR200 Compiler

Use this setting to select the directory and executable name that will be used to

pre-compile the CR200/205 program to check for errors.

Most Campbell Scientific dataloggers are sent an ASCII program file, which

they then compile into machine code. The CR200/205 does not have enough

memory and processing capability to do this compilation, so it’s necessary to

compile the program file into the binary version used by the datalogger itself.

This compilation is done by Short Cut to check for errors in the program before

sending it. It’s done again by LoggerNet, RTDAQ, PC400, or PC200W when

sending the program to the datalogger. Compilation is performed using a

special executable that mimics the functions and capability in the datalogger’s

operating system. Therefore, the compiler executable must match the

datalogger’s operating system or the datalogger may fail to run the compiled

binary (*.BIN) program. LoggerNet, RTDAQ, PC400, PC200W, and Short

Cut are installed with precompilers for all of the released versions of the

CR200/205 operating systems. If, at some time in the future, you acquire a

newer CR200/205, or choose to install a later operating system, you must make

sure you also have the compiler executable that matches. These compiler

executables are typically installed in a library directory. By default, this

directory would be installed as:

C:\Campbellsci\Lib\CR200Compilers

If you receive an operating system update, you should copy the compiler

associated with it to this directory. If, for some reason, you put the compiler in

a different directory, this menu item provides a way to choose that compiler

executable.

7.2.3.5 Sensor Support

The Sensor Support option is used to select which group of sensor files will be

displayed when creating a program: Campbell Scientific, Inc., (CSI) or

Campbell Scientific, Ltd. (CSL). The standard set of Short Cut sensor files

was created by CSI; however, CSL has created some additional files that are

customized for their client base. When one option is selected, the sensor files

developed specifically for the other are filtered out.

This dialog box is displayed the very first time you create a program for a

specific datalogger type; it will not be displayed thereafter. With each

subsequent program you create, the group of sensor files that you chose when

the datalogger was initialized in Short Cut will be used. However, you can

change this setting at any time. If you make a change, the setting will remain

in effect for all programs for that datalogger type (whether they are new

programs or edited programs) until it is changed again.