15 time synchronization, Time synchronization -71 – Campbell Scientific LoggerNet Datalogger Support Software User Manual

Page 369

Advertising
background image

Section 8. Working with Data Files on the PC

A single expression can operate on a set of elements. For example, the

expression (3..6,8)/2.0 is the same as 3/2.0, 4/2.0, 5/2.0, 6/2.0, 8/2.0;

(3..6)/(2..5) is the same as 3/2, 4/3, 5/4, 6/5.

The element or expression that is the argument of a math or Time Series

function, must be enclosed in parentheses. A range of elements can be

specified, resulting in as many outputs as elements (e.g., Avg(3..5,7) will

output 4 averages).

Square brackets are used to enclose an allowable range for a value (e.g.,

3[3.6..12] ) to indicate that the allowable range for element 3 is from 3.6 to

12. Whole numbers within brackets do not require a decimal point. TABLE

8-5 explains how values outside the specified range are treated.

The interval in a Time Series function is optional and does not require a

decimal point.

Semicolons are used in Time Series functions to separate the elements or

expressions from the number that determines the interval. Sample on

maximum and sample on minimum require two elements or expressions

also separated by a semicolon.

8.2.3.1.15 Time Synchronization

The time synchronize function is useful when data is missing from a file or if

several files of data need to be merged together. The files are synchronized

according to time; any missing data in the file (or files) will be replaced with

blank data.

This function synchronizes according to day, hrmn (hour-minute), and/or

seconds. The syntax used to identify the time elements for array data is:

e

i

[day]:e

i

[hrmn]:e

i

[seconds]

Referring to TABLE 8–1, to identify the day of year for a mixed-array data

file, type:

2[189]::

for hrmn type:

:3[1200]:

and seconds are expressed as:

::4[5]

A single colon is assumed to be between day and hrmn (e.g., 2[189]: means

day, :3[1200] means hours, and 2[189]:3[1200] means day and hour-minute).

When the time synchronize function is used, a time interval must be specified

in the Copy line of the first data file. For example, 4[60] in the Copy line will

create a synchronized file containing the data from the input files that occurred

every 60 minutes. If no time interval is specified in the Copy line then the time

specified in the Start Condition becomes simply a starting time with no time

synchronization.

8-71