3 renaming network devices, 4 device settings, 1 comport – Campbell Scientific LoggerNet Datalogger Support Software User Manual

Page 63: Renaming network devices -7, Device settings -7, Comport -7

Advertising
background image

Section 4. Setting up Datalogger Networks

4.2.3 Renaming Network Devices

The names of all of the devices can be changed as desired. Rename a device

by selecting the device and either clicking again with the left mouse button on

the selected device or clicking the Rename button. The name of the selected

device will change to a text edit box and the new device name can be entered.

Valid names consist of letters, numbers and the underscore (_). The device

name must be unique in the network and the first character must be a letter.

Device names can reflect a location, layout, or physical location of network

devices. Think carefully when naming the devices since these names are used

throughout LoggerNet to refer to the devices.

4.2.4 Device Settings

When you highlight any device on the network shown on the left side of the

Setup Screen, configuration tabs appear on the right side with the relevant

settings. These settings are different for different devices and are described in

detail below. Some of the tabs have a Standard section and an Advanced

section. The Standard section contains information that must be reviewed to

ensure it matches the settings for the device. The Advanced section contains

settings that can be left at the default for most applications.

All devices have a Notes tab which is only for the user’s convenience. It may

be used to keep notes about the device for future reference.

As with changes to the network map, the changes made to the device settings

are not used until they have been applied.

4.2.4.1 ComPort

The ComPort (or serial port) has only Hardware and Notes tabs. Following is

an explanation of each of the fields on the Hardware tab.

Standard
Communications Enabled – Before communications can take place, all

devices in the communications chain must be enabled. The default setting for

this check box is Enabled.

ComPort Connection – This field designates the communications port

through which you will be connecting to the datalogger. Select the arrow to

the right of the field with a mouse to display a list containing the ComPorts that

are set up on your computer.

Advanced
Call-Back Enabled – Enabling call-back tells LoggerNet to watch for a call-

back from the datalogger on this port. If there is a phone modem attached it

will be set to accept incoming calls.

Dataloggers depicted in the Setup Screen must be configured for call-back as

well. For mixed array dataloggers, set the Call-Back ID to some value other

than 0 to accomplish this. For CRBasic dataloggers, enable the Call-Back

Enabled check box for those dataloggers which should be enabled for call-

back.

4-7

Advertising