B.1 parameters of the sfc-dc, B.1.1 general parameter structure, Parameters of the sfc−dc – Festo Контроллер двигателя SFC-ST User Manual

Page 117: B.1.1, General parameter structure

Advertising
background image

B. Supplementary information

B−3

Festo P.BE−SFC−DC−PB−S7−E N en 0604NH

B.1

Parameters of the SFC−DC

B.1.1

General parameter structure

Group

Indices

Description

Device data

100 ... 199

Device identification and device−specific settings, version
numbers, identifier words, etc.

Diagnostic memory

200 ... 299

Memory for diagnostic events: Fault numbers, fault time,
incoming/outgoing event

Processing data

300 ... 399

Current nominal and actual values, local I/Os, status data etc.

Record list

400 ... 499

A record contains all the nominal value parameters required
for a positioning procedure

Project data

500 ... 599

Basic project settings. Maximum speed and acceleration,
offset project zero point etc.

–> Parameters are the basis for

the record list.

Factor group

600 ... 699

Reserved

Axis data
Electric drives 1

1000 ... 1099

All axis−specific parameters for electric drives. Gear factor,
feed constant, reference parameter ...