B.1 parameters of the sfc-dc, B.1.1 general parameter structure, Parameters of the sfc−dc – Festo Контроллер двигателя SFC-ST User Manual
Page 117: B.1.1, General parameter structure
B. Supplementary information
B−3
Festo P.BE−SFC−DC−PB−S7−E N en 0604NH
B.1
Parameters of the SFC−DC
B.1.1
General parameter structure
Group
Indices
Description
Device data
100 ... 199
Device identification and device−specific settings, version
numbers, identifier words, etc.
Diagnostic memory
200 ... 299
Memory for diagnostic events: Fault numbers, fault time,
incoming/outgoing event
Processing data
300 ... 399
Current nominal and actual values, local I/Os, status data etc.
Record list
400 ... 499
A record contains all the nominal value parameters required
for a positioning procedure
Project data
500 ... 599
Basic project settings. Maximum speed and acceleration,
offset project zero point etc.
–> Parameters are the basis for
the record list.
Factor group
600 ... 699
Reserved
Axis data
Electric drives 1
1000 ... 1099
All axis−specific parameters for electric drives. Gear factor,
feed constant, reference parameter ...