3 converting the measuring units, Converting the measuring units, Special conversion factors for the sfc−dc – Festo Контроллер двигателя SFC-ST User Manual

Page 59

Advertising
background image

4. Parametrizing blocks

4−5

Festo P.BE−SFC−DC−PB−S7−E N en 0604NH

4.1.3

Converting the measuring units

In the SFC−DC all parameters are always saved in increment
specifications (inc, inc/s, inc/s

2

). Conversion is carried out via

the parameters:

ć

Feed constant, depending on the drive

ć

Gear reduction

ć

Encoder resolution = physical measuring steps per motor
revolution. With the SFC−DC: pulse quadruplication by
digital interpolation.

Parameters

SLTE−10

SLTE−16

feed

Feed constant

1)

SLTE−...−BS5.0: 5000 [Ģm/rev]

SLTE−...−LS7.5: 7500 [Ģm/rev]

gear

Gear ratio

2)

SLTE−...−G04 (57:13)

enc

Encoder resolution

3)

512 x 4 = 2048 [incr/rev]

1000 x 4 = 4000 [incr/rev]

1) D

epending on drive, here type SLTE−...

2)

Specification in 2 natural numbers for counter or denominator of the fraction

3)

With the SFC−DC: pulse quadruplication by digital interpolation

Tab. 4/1:

Basis parameter for the measuring system

The values for specifying the positions in Ģm are saved in the
SFC−DC and can be downloaded (PNU 1004, subindex 0 and 1).

Special conversion factors for the SFC−DC

Length unit

SLTE−10

SLTE−16

Increments

> millimetres

Increments / 1795.938

Increments / 2338.461

Millimetre

> increments

Millimetres * 1795.938

Millimetres * 2338.461

Increments

> inch

Increments / 45616.836

Increments / 59396.923

Inch

> increments

Inch * 45616.836

Inch * 59396.923

Tab. 4/2:

Conversion factors for SLTE measuring system

Advertising