4. Parametrizing blocks
4−15
Festo P.BE−SFC−DC−PB−S7−E N en 0604NH
4.4.4
Implementation
The block PRM_DB−FILE cannot function on its own, only in
combination with one of the transfer blocks can it transfer a
list of parameters. Some of the inputs or outputs must thereĆ
fore be linked directly with each other.
RD_WR_DB−FILE
<−>
PRM_...
_PNU
OUTPUT
−−>
_PNU
INPUT
_Subindex
OUTPUT
−−>
_Subindex
INPUT
_Length_RD
OUTPUT
−−>
_Length
INPUT
_Value_WR
OUTPUT
−−>
_Value_WR
INPUT
_Done_RD_WR
INPUT
<−−
_Done_RD_WR
OUTPUT
_Fault_RD_WR
INPUT
<−−
_Fault_RD_WR
OUTPUT
_Value_RD
INPUT
<−−
_Value_RD
OUTPUT
Tab. 4/9:
Wiring table
4.4.5
Restriction
Function block RD_WR_DB−File uses internally the system
function SFC24. With this function the source and target DB
can be tested and their length defined. However, this function
is not implemented in controllers of an earlier date. The block
cannot therefrore be used there in this form.