4. Parametrizing blocks

4−16

Festo P.BE−SFC−DC−PB−S7−E N en 0604NH

4.5

Fault information

A distinction is always made between two types of faults:
block faults and transmission faults.

Block faults (e.g. incorrect logic address, incorrect hardware
configuration, etc.) are caused by the relevant system funcĆ
tion blocks used SFC14/SFC15, SFC58/SFC59, SFB52/SFB53
or SFC24 and shown at the output RET_VALUE. The fault code
can be found in the STEP 7 help. If a block fault occurs, the
block will be exited with the ENO bit = 0.

Transmission faults arise as a result of incorrect parameter
data (e.g. non−existent PNU, incorrect parameter length when
writing, non−existent subindex, etc.).
Transmission faults are shown with the bit Fault.
With the aid of the value of Value_RD the fault can be evaluĆ
ated accordingly Tab. 4/10.

Fault numbers

Description

0

0x00

Non−permitted PNU The parameter does not exist.

1

0x01

Parameter value cannot be modified (read only)

(2)

0x02

ć (reserved ć lower or upper limit value exceeded)

1)

3

0x03

Faulty subindex

4

0x04

No array

5

0x05

Incorrect data type

(6)

0x06

ć (reserved ć setting not permitted ć can only be reset)

1)

(7)

0x07

ć (reserved ć describing element cannot be modified)

1)

(8)

0x08

ć (reserved ć PPO−Write requested in IR does not exist)

1)

9

0x09

Description data do not exist

(10)

0x10

ć (reserved ć access group incorrect)

1)

11

0x0A

No control sovereignty

(12)

0x0B

ć (reserved ć password incorrect)

1)

1)

These fault numbers are not used