1 input parameters, 2 output parameter, Input parameters – Festo Контроллер двигателя SFC-ST User Manual

Page 61: Output parameter

Advertising
background image

4. Parametrizing blocks

4−7

Festo P.BE−SFC−DC−PB−S7−E N en 0604NH

4.2.1

Input parameters

Parameters

DeclaĆ
ration

Data
type

Description

I_ADDRESS

INPUT

WORD

Logical input address of the FPC (PKW) specifications

O_ADDRESS

INPUT

WORD

Logical output address of the FPC (PKW) specifications

RD_WR

INPUT

BOOL

FALSE: Read
TRUE:

Write

Start

INPUT

BOOL

Starts write or read procedure

PNU

INPUT

WORD

Parameter number of the current parameter

Subindex

INPUT

BYTE

Subindex of the current parameter

Length

INPUT

INT

Length of the parameter to be written in bytes

Param_
Value_WR

INPUT

DWORD

Parameter value when writing a parameter

Tab. 4/3:

Input parameter PRM_FPC

4.2.2

Output parameter

Parameters

DeclaĆ
ration

Data
type

Description

Done

OUTPUT

BOOL

FALSE: Transfer completed
TRUE:

Write

Value_RD

OUTPUT

DWORD

Value of parameter to be read

Length_RD

OUTPUT

INT

Length of parameter to be transferred

Fault

OUTPUT

BOOL

FALSE: No fault
TRUE:

Fault

RET_VAL

OUTPUT

INT

Return value after incorrect processing of the block

Tab. 4/4:

Output parameter PRM_FPC