3. Control block

3−8

Festo P.BE−SFC−DC−PB−S7−E N en 0604NH

3.1.3

Output parameters

Parameter

DeclarĆ
ation

Data
type

Description

Control_FCT_HMI

OUTPUT

BOOL

Control sovereignty PLC or MMI/FCT.
FALSE: Control sovereignty PLC
TRUE:

Control sovereignty MMI/FCT (PLC control is
Locked).

Drive_enabled

OUTPUT

BOOL

Drive enabled.
FALSE: Drive blocked, controller not active.
TRUE:

Drive (controller) enabled.

Supply_Voltage_
Ok

OUTPUT

BOOL

Load voltage
FALSE: No load voltage
TRUE:

Load voltage applied

Warning

OUTPUT

BOOL

Warning.
FALSE: Warning not applied
TRUE:

Warning applied

Fault

OUTPUT

BOOL

Fault
FALSE: No fault
TRUE:

There is a fault or reaction to fault is active.
Fault number in diagnostic memory

Ready

OUTPUT

BOOL

Quit stop, if Drive_enable" = 1

State_Operation_
Mode

OUTPUT

BOOL

Reply message operating mode
FALSE: Record Select (standard)
TRUE:

Direct mode

Ack_Start

OUTPUT

BOOL

Quit Start
FALSE: Ready for start (reference, jog)
TRUE:

Start carried out (reference, jog)

Ack_Teach

OUTPUT

BOOL

Quit Teach
positive edge:

Ready for teaching

negative edge:

Teaching carried out
Actual value is transferred.