Festo Контроллер двигателя SFC-ST User Manual
Page 122

B. Supplementary information
B−8
Festo P.BE−SFC−DC−PB−S7−E N en 0604NH
Name
FHPP
Name
Access
2)
Type
Subind.
1)
PNU
Axis data electric drives 1 ć electronic type plate
Motor Type
1030
ć
uint16
rw2
Maximum Current
1034
ć
uint16
rw2
Motor Rated Current
1035
ć
uint32
rw2
Axis data electric drives 1 ć standstill monitoring
Position Target Value (nominal position)
1040
ć
int32
ro
Position Actual Value (current position)
1041
ć
int32
ro
Contouring Error Window (standstill position window)
1042
ć
uint32
rw2
Contouring Error Timeout (standstill monitoring time)
1043
ć
uint16
rw2
1)
Subindices of the parameter for FHPP with access via parametrizing blocks (0...n−1)
2)
ro = read only;
wo = write only;
rw/rw1 = read and write at any time;
rw2 = read and write during commissioning
Tab. B/1: