4. Parametrizing blocks

4−9

Festo P.BE−SFC−DC−PB−S7−E N en 0604NH

4.3.1

Input parameters

Parameters

DeclaĆ
ration

Data
type

Description

I_O_ADDRESS

INPUT

WORD

Logical address of the DP slave module
Example: I−address 256, O−address 264
−−> W#16#100
The smaller of the two addresses must be specified.

RD_WR

INPUT

BOOL

0 = read
1 = write

Start

INPUT

BOOL

Starts write or read procedure

PNU

INPUT

WORD

Parameter number of the current parameter

Subindex

INPUT

BYTE

Subindex of the current parameter

Length_WR

INPUT

INT

Length of the parameter to be written in bytes

Value_WR

INPUT

DWORD

Parameter value when writing

Tab. 4/5:

Input parameters PRM_DPV1_SFB / PRM_DPV1_SFC

4.3.2

Output parameters

Parameters

DeclaĆ
ration

Data
type

Description

Done

OUTPUT

BOOL

Transfer completed

Value_RD

OUTPUT

DWORD

Value of parameter to be read

Length_RD

OUTPUT

INT

Length of parameter to be transferred

Fault

OUTPUT

BOOL

Fault bit

RET_VAL

OUTPUT

INT

Return value after incorrect processing of the block

Tab. 4/6:

Output parameters PRM_DPV1_SFB / PRM_DPV1_SFC