Description of method of operation

The block enables the drive functions of the SFC−DC to be
controlled by the field bus. It enables comfortable access to
the control bits.

System functions used

For data exchange the block uses internally the system funcĆ
tions SFC14/SFC15.

The correct logical input and output addresses of the slave
projected in the Hardware Manager must be entered for the
data exchange.

Position factor

All position specifications are always saved internally in
increments in the SFC−DC.

In the control block the conversion between increments and
the desired measuring system takes place via a position facĆ
tor. The position factor is defined by a counter and a denomiĆ
nator value.

Unit of length

Parameter

SLTE−10

SLTE−16

Increments

Pos_Faktor_nummerator:
Pos_Faktor_denummerator:

ă1 000 000
ă1 000 000

ă1 000 000
ă1 000 000

Ģm

Pos_Faktor_nummerator:
Pos_Faktor_denummerator:

ă1 795 938 (default)
ă1 000 000

ă2 338 461
ă1 000 000

ĢInch

Pos_Faktor_nummerator:
Pos_Faktor_denummerator:

45 616 836
ă1 000 000

59 396 923
ă1 000 000

Tab. 3/1:

SFC−DC position factors with the electric mini−slide type SLTE