2. Installation and project overwiev
2−6
Festo P.BE−SFC−DC−PB−S7−E N en 0604NH
Insert SFC−DC as slave
The hardware configuration window represents graphically
the structure of the master system. When the GSD file has
been installed, the SFC−DC can be selected in the hardware
catalogue. It can be found in the group [PROFIBUS−DP]
[Additional Field Devices] [Drives] [Festo], (see Fig. 2/1).
In order to insert the SFC−DC:
1. Drag the station type Festo SFC−DC" or Festo SFC−DC
DP−V0" (āā
3ā, see section 2.1.1) from the hardware
catalogue onto the PROFIBUS line (āā
1āā) of the DP master
system (Drag & Drop).
2. Enter the PROFIBUS address, which you have set with the
Festo Configuration Tool or on the control panel in the
dialogue window Properties PROFIBUS interface..." and
confirm with OK.
3. If necessary, enter other settings in the dialogue window
Properties DP slave" (e.g. the response monitoring or
the startup parametrizing) and confirm with OK.
The icon of the SFC−DC is displayed on the line of the DP
master system (āā
2āā).