Specification chart, Specifications chart – JLG G6-42P Service Manual User Manual

Page 499

Advertising
background image

SPECIFICATIONS CHART

Part

Number

Brake

Port

Pressure

Port

Flow Thru

Port

Return

Port

Brake

Line Pressure

(with power)

Flow

Capacity

* 06-460-520

1/2-20 UNF

SAE No. 10

SAE No. 10

1/2-14 NPTF

1850 psi ± 50 psi

3-24 gpm

Complete unit replaced by 06-460-658

06-460-522

9/16-18 UNF

SAE No. 10

SAE No. 10

SAE No. 10

1850 psi ± 50 psi

3-24 gpm

* 06-460-550

1/2-20 UNF

SAE No. 10

SAE No. 10

1/2-14 NPTF

1500 psi ± 50 psi

3-24 gpm

Complete unit replaced by 06-460-656

* 06-460-560

1/2-20 UNF

SAE No. 8

SAE No. 8

SAE No. 10

1550 psi ± 50 psi

3-24 gpm

Complete unit replaced by 06-460-656

* 06-460-570

9/16-18 UNF

SAE No. 8

SAE No. 8

SAE No. 10

1550 psi ± 50 psi

3-24 gpm

Complete unit replaced by 06-460-662

* 06-460-580

1/2-20 UNF

SAE No. 10

SAE No. 10

SAE No. 10

1500 psi ± 50 psi

3-24 gpm

Complete unit replaced by 06-460-656

* 06-460-588

1/2-20 UNF

SAE No. 10

SAE No. 10

SAE No. 10

1550 psi ± 50 psi

3-24 gpm

Complete unit replaced by 06-460-664

* 06-460-610

9/16-18 UNF

SAE No. 10

SAE No. 10

1/2-14 NPTF

950 psi ± 50 psi

3-24 gpm

Complete unit replaced by 06-460-666

* 06-460-620

1/2-20 UNF

SAE No. 10

SAE No. 10

SAE No. 10

1500 psi ± 50 psi

3-24 gpm

Complete unit replaced by 06-460-656

06-460-642

1/2-20 UNF

SAE No. 10

SAE No. 10

SAE No. 10

1550 psi ± 50 psi

3-24 gpm

* 06-460-650

1/2-20 UNF

SAE No. 10

SAE No. 10

1/2-14 NPTF

1500 psi ± 50 psi

3-24 gpm

Complete unit replaced by 06-460-656

* 06-460-654

9/16-18 UNF

SAE No. 8

SAE No. 8

SAE No. 10

1500 psi ± 50 psi

3-12 gpm

Complete unit replaced by 06-460-676

* 06-460-656

1/2-20 UNF

SAE No. 10

SAE No. 10

SAE No. 10

1500 psi ± 50 psi

3-24 gpm

* 06-460-658

1/2-20 UNF

SAE No. 10

SAE No. 10

SAE No. 10

1850 psi ± 50 psi

3-24 gpm

* 06-460-660

1/2-20 UNF

SAE No. 10

SAE No. 10

SAE No. 10

1150 psi ± 50 psi

3-24 gpm

* 06-460-662

9/16-18 UNF

SAE No. 10

SAE No. 10

SAE No. 10

1550 psi ± 50 psi

3-24 gpm

* 06-460-664

1/2-20 UNF

SAE No. 10

SAE No. 10

SAE No. 10

1500 psi ± 50 psi

3-12 gpm

* 06-460-666

9/16-18 UNF

SAE No. 10

SAE No. 10

SAE No. 10

950 psi ± 50 psi

3-24 gpm

06-460-668

1/2-20 UNF

SAE No. 10

SAE No. 10

SAE No. 10

1000 psi ± 50 psi

3-12 gpm

* 06-460-670

SAE No. 10

SAE No. 10

SAE No. 10

1550 psi ± 50 psi

3-8 gpm

06-460-672

1/2-20 UNF

SAE No. 10

SAE No. 10

SAE No. 10

750 psi ± 50 psi

3-24 gpm

* 06-460-674

1/2-20 UNF

SAE No. 10

SAE No. 10

SAE No. 10

1500 psi ± 50 psi

3-12 gpm

06-460-676

9/16-18 UNF

SAE No. 10

SAE No. 10

SAE No. 10

1500 psi ± 50 psi

3-12 gpm

06-460-678

1/2-20 UNF

SAE No. 10

SAE No. 10

SAE No. 10

1700 psi ± 50 psi

3-24 gpm

* 06-460-680

1/2-20 UNF

SAE No. 8

SAE No. 8

SAE No. 10

1550 psi ± 50 psi

3-8 gpm

Complete unit replaced by 06-460-670

06-460-682

1/2-20 UNF

SAE No. 8

SAE No. 8

SAE No. 10

750 psi ± 50 psi

3-24 gpm

Complete unit replaced by 06-460-672

06-460-684

1/2-20 UNF

SAE No. 10

SAE No. 10

SAE No. 10

1100 psi ± 50 psi

3-12 gpm

* 06-460-686

1/2-20 UNF

SAE No. 10

SAE No. 10

1/2-14 NPTF

1500 psi ± 50 psi

3-12 gpm

Complete unit replaced by 06-460-674

06-461-520

1/2-20 UNF

SAE No. 10

SAE No. 10

1/2-14 NPTF

1850 psi ± 50 psi

3-24 gpm

Complete unit replaced by 06-461-658

06-461-550

1/2-20 UNF

SAE No. 10

SAE No. 10

1/2-14 NPTF

1500 psi ± 50 psi

3-24 gpm

Complete unit replaced by 06-461-656

06-461-610

9/16-18 UNF

SAE No. 10

SAE No. 10

1/2-14 NPTF

950 psi ± 50 psi

3-24 gpm

Complete unit replaced by 06-461-666

06-461-656

1/2-20 UNF

SAE No. 10

SAE No. 10

SAE No. 10

1500 psi ± 50 psi

3-24 gpm

06-461-658

1/2-20 UNF

SAE No. 10

SAE No. 10

SAE No. 10

1850 psi ± 50 psi

3-24 gpm

06-461-660

1/2-20 UNF

SAE No. 10

SAE No. 10

SAE No. 10

1150 psi ± 50 psi

3-24 gpm

06-461-666

9/16-18 UNF

SAE No. 10

SAE No. 10

SAE No. 10

950 psi ± 50 psi

3-24 gpm

06-461-674

1/2-20 UNF

SAE No. 10

SAE No. 10

SAE No. 10

1500 psi ± 50 psi

3-12 gpm

• For use with drum brakes (has residual check valve)

NOTE: The valves should be used within the flow capacities indicated above for optimum performance. Valves are functional
at lower flows but response is reduced. At the higher flow operation higher pressure drops are seen.

(7)

1/2-20 UNF