Section 6 - Emergency Procedures

6-2

31200148

6.2

EMERGENCY LOWER OF BOOM

In the event of total loss of engine power or hydraulic pump failure with an elevated
load, the situation must be properly evaluated and dealt with on an individual basis.
Contact your local Authorized Distributor for specific instructions.

Secure the telehandler using the following procedures:

1. Clear the area around telehandler of all personnel.

2. Engage the parking brake. Place the transmission control lever in “NEUTRAL”.

3. Block all four wheels.

4. Section off a large area under the boom with string or tape to restrict any

personnel from entering this area.

6.3

EMERGENCY EXIT FROM ENCLOSED CAB

IIn an emergency, an escape hammer, located directly below the rear window in an
enclosed cab, can be used to exit the telehandler.