4.13 PLATFORM CONTROL ENABLE SYSTEM

The platform controls make use of a time dependent enable
circuit to limit the time availability of “live” or enabled controls.
When the footswitch is depressed, the controls are enabled
and the operator has 7 seconds to operate any control. The
controls will remain enabled as long as the operator continues
to use any function and will remain enabled 7 seconds after

the last function has been used. While the controls are “live”,
the enabled light will be illuminated in the platform display
panel. When the time limit has been reached, the enabled
light will turn off and the controls will be disabled. To con-
tinue use of the machine the controls must be re-enabled to
start the timer system over again. This is done by releasing all
functions, then releasing and re-depressing the footswitch.

A
B
C
D

Torque to 54 ft.lbs. (73 Nm)
Loctite #242
Torque 565 ft. lbs. (766 Nm)
Check torque every 150 hours of operation

Figure 4-15. Platform Support Torque Values

NOTE:

If any rotator bolts are replaced,
all bolts on the rotator should
be retorqued.