JLG 24RS Service Manual User Manual

Page 211

Advertising
background image

SECTION 6 - JLG CONTROL SYSTEM

3121287

– JLG Lift –

6-35

FUNCTION PROBLEM - TELE-
SCOPE IN PERMANENTLY
SELECTED

2251

The machine is in Platform mode and the telescope switch is sending
a continual telescope in signal.

Machine enters Creep Mode
and Tele In and Out prohibited.

Release the footswitch and
return the telescope switch to
neutral. Actuate switch while
monitoring state changes
under appropriate menu in
DIAGNOSTICS-->OPER CON-
TROLS on Analyzer. Replace the
switch if faulty.

FUNCTION PROBLEM - TELE-
SCOPE OUT PERMANENTLY
SELECTED

2252

The machine is in Platform mode and the telescope switch is sending
a continual telescope out signal.

Machine enters Creep Mode
and Tele In and Out prohibited.

Release the footswitch and
return the telescope switch to
neutral. Replace the switch if
faulty.

FUNCTION PROBLEM - PLAT-
FORM LEVEL UP PERMA-
NENTLY SELECTED

2262

The machine is in Platform mode and the platform level up switch is
sending a continual level up signal.

Machine enters Creep Mode
and Platform Level Up and
Down prohibited.

Release the footswitch and
return the platform level switch
to neutral. Actuate switch
while monitoring state
changes under appropriate
menu in DIAGNOSTICS-->OPER
CONTROLS on Analyzer.
Replace the switch if faulty.

FUNCTION PROBLEM - PLAT-
FORM LEVEL DOWN PERMA-
NENTLY SELECTED

2263

The machine is in Platform mode and the platform level down switch
is sending a continual level up signal.

Machine enters Creep Mode
and Platform Level Up and
Down prohibited.

Release the footswitch and
return the platform level switch
to neutral. Actuate switch
while monitoring state
changes under appropriate
menu in DIAGNOSTICS-->OPER
CONTROLS on Analyzer.
Replace the switch if faulty.

FUNCTION SWITCHES FAULTY -
CHECK DIAGNOSTICS/BOOM

234

The Ground Module detects one of the following conditions:

The machine is in Ground Mode and both direction inputs of the
following boom controls are energized at the same time: Engine
Start/Aux, Telescope, Platform Level, Platform Rotate, Lift, or
Swing.

The machine is in Platform Mode and both direction inputs of the
following boom controls are energized at the same time: Engine
Start/Aux, Telescope, Platform Level, Platform Rotate

The boom function that is trig-
gering the fault is disabled.
NOTE: If Engine Start/Aux
Power is at fault, Emer-
gency Descent will still be
permitted.

Check the switch for the appli-
cable function. Actuate switch
while monitoring state
changes under appropriate
menu in DIAGNOSTICS-->OPER
CONTROLS on Analyzer.
Replace if faulty.

FUNCTION SWITCHES LOCKED
- SELECTED BEFORE AUX
POWER

235

The Ground Module detects one of the following conditions:

The machine is in Ground Mode, the engine is stopped, and the
ground Auxiliary Descent switch is selected after a Ground con-
trol switch has been selected.

The machine is in Platform Mode, the engine is stopped, and the
platform Auxiliary Descent switch is selected after a Platform
control switch has been selected.

Emergency Descent mode is
disabled

Release all function switches.
Activate the Auxiliary Descent
switch before any other appli-
cable control switches or start
the engine

Table 6-5. Fault Code Troubleshooting Information

Help Message

DTC

Condition Producing DTC

Control System Response or

Machine Condition

Corrective Action/

Operational Requirement

for Function Movement

and/or to Clear Fault

Advertising