JLG 24RS Service Manual User Manual

Page 212

Advertising
background image

SECTION 6 - JLG CONTROL SYSTEM

6-36

– JLG Lift –

3121287

FUNCTION SWITCHES LOCKED
- SELECTED BEFORE START
SWITCH

236

The Ground Module detects one of the following conditions:

The machine is in Ground Mode, the engine is stopped, and any
boom control is selected before the ground engine start switch is
selected.

The machine is in Platform Mode, the engine is stopped, any
drive/steer or boom control is already engaged and the foot-
switch is not engaged before the platform engine start switch is
selected

Engine start is disabled

Release all function switches.
Start the engine before any
other applicable function
switches are selected.

START SWITCH LOCKED -
SELECTED BEFORE KEY-
SWITCH

237

The engine start switch for the selected station is engaged during the
Ground Module startup sequence.

Engine start is disabled

Release the engine start
switch. Position the Ground/
Platform Select switch to the
opposite operating station to
verify the engine can be
started. View switch state on
Analyzer under DIAGNOSTICS--
>OPER CONTROLS-->START
SWITCH.

FUNCTION PROBLEM -
GROUND ENABLE PERMA-
NENTLY SELECTED

2310

The machine is in Ground mode and the Enable switch is in the
selected position.

Disable Start and Boom func-
tions, including Emergency
Descent.

Return the switch to the off
position. View switch state on
Analyzer under DIAGNOSTICS--
>OPER CONTROLS-->AUX
DESCENT SW. Replace the
switch if defective.

FUNCTION PROBLEM - SWING
LEFT PERMANENTLY
SELECTED

2372

The machine is in Ground mode and the Swing switch is selected and
trying to activate the Swing Left function at startup.

Swing Left and Right prohib-
ited.

With the machine controls not
enabled, return the Swing
switch to neutral. Actuate
switch while monitoring state
changes under appropriate
menu in DIAGNOSTICS-->OPER
CONTROLS on Analyzer.
Replace the switch if defective.

FUNCTION PROBLEM - SWING
RIGHT PERMANENTLY
SELECTED

2373

The machine is in Ground mode and the Swing switch is selected and
trying to activate the Swing Right function at startup.

Swing Left and Right prohib-
ited.

With the machine controls not
enabled, return the Swing
switch to neutral. Actuate
switch while monitoring state
changes under appropriate
menu in DIAGNOSTICS-->OPER
CONTROLS on Analyzer.
Replace the switch if defective.

BOOM TRANSPORT SWITCH
DISAGREEMENT

23104

The Ground Module detects that Boom Elevation switch #1 and
switch #2 are not in agreement for more than 4 seconds while lifting.

The Ground Module assumes
an "Above Elevation" condition
and does not allow Axle Oscilla-
tion.

Verify that the two boom angle
switches are adjusted to actu-
ate simultaneously. Cycle
Power.

Table 6-5. Fault Code Troubleshooting Information

Help Message

DTC

Condition Producing DTC

Control System Response or

Machine Condition

Corrective Action/

Operational Requirement

for Function Movement

and/or to Clear Fault

Advertising