SECTION 3 - CHASSIS & TURNTABLE

3121287

– JLG Lift –

3-55

b. Disconnect the supply line coming from the hydrau-

lic tank.

3.

Remove the mounting bolts and washers securing the
auxiliary pump to the turntable and remove the auxil-
iary pump.

4.

Disconnect the negative cable from the auxiliary pump.

Installation

1.

Connect the negative cable to the auxiliary pump.

2.

Coat the mounting bolts with Loctite #242 and use the
bolts and washers to attach the auxiliary pump to the
turntable. Torque the bolts to 40 ft.lbs. (55 Nm).

3.

Connect the hydraulic lines to the motor as tagged dur-
ing removal.

a. Torque the hydraulic line running to the main con-

trol valve to 13 ft.lbs. (18 Nm).

b. Torque the supply line coming from the hydraulic

tank to 23 ft.lbs. (32 Nm).

4.

Connect the positive terminal to the motor.

5.

Operate the pump and check for proper function and
any sign of leakage.