SECTION 6 - JLG CONTROL SYSTEM

3121287

– JLG Lift –

6-57

Table 6-6. Overload Variations

BROADCAST ONLY

3

WARN ONLY

CUTOUT ALL

SPECIAL 1

(Access Industries)

CUTOUT PLATFORM

Platform

Activate visual overload light at
Platform Station

Activate visual overload light at
Platform Station

Activate System Distress and Over-
load lights at Platform station

Activate visual overload light at
Platform Station

Activate System Distress and
Overload lights at Platform sta-
tion

Activate Platform and Ground Alarm
– 5 sec ON, 2 sec OFF

Activate Platform and Ground Alarm
– 5 sec ON, 2 sec OFF

Activate Platform and Ground Alarm
– 5 sec ON, 2 sec OFF

Activate Platform and Ground Alarm
– on continuously

Activate Platform and Ground
Alarm – 5 sec ON, 2 sec OFF

Do not report Fault

Activate creep mode all functions,
energize Creep light, and report
Fault

Do not permit Machine Enable (no
creep light) and report Fault

Activate creep mode all functions,
energize Creep light, and report
Fault

Do not permit Machine Enable
(no creep light) and report Fault

Disable Telescope Out and Lift Up

Ground

Activate visual overload light
(Ground Station)

Activate visual overload light
(Ground Station)

Activate visual overload light
(Ground Station)

Activate visual overload light
(Ground Station)

Activate visual Overload light at
Ground Station

Activate Platform and Ground Alarm
– 5 sec ON, 2 sec OFF

Activate Platform and Ground Alarm
– 5 sec ON, 2 sec OFF

Activate Platform and Ground Alarm
– 5 sec ON, 2 sec OFF

Activate Platform and Ground Alarm
– on continuously

Activate Platform and Ground
Alarm – 5 sec ON, 2 sec OFF

Do not report Fault

Report Fault

Report Fault

Do not report Fault

Do not report fault.

Activate creep mode all functions

Do not permit Machine Enable (no
creep light)

Overload shall have no effect on
function speeds.

Overload shall have no effect on
function speeds.

Auxiliary Power/Emergency Descent

Platform operation and annuncia-
tion as Platform Mode above

Platform operation and annuncia-
tion as Platform Mode above

Platform operation and annuncia-
tion as Platform Mode above, except
do not disable all functions

Platform operation and annuncia-
tion as Platform Mode above

Platform operation and annunci-
ation as Platform Mode above,
except do not report Fault or dis-
able all functions

Ground operation and annunciation
as Ground Mode above, except do
not activate creep mode

Ground operation and annunciation
as Ground Mode above, except do
not activate creep mode

Ground operation and annunciation
as Ground Mode above, except do
not report Fault or disable all func-
tions

Ground operation and annunciation
as Ground Mode above

Ground operation and annuncia-
tion as Ground Mode above

Faults

No applicable fault

When the platform is overloaded,
report “RUNNING AT CREEP - PLAT-
FORM OVERLOADED.”

When the platform is overloaded,
report "DRIVE & BOOM PREVENTED
– PLATFORM OVERLOADED."

When the platform is overloaded,
report "LIFT UP & TELE OUT PRE-
VENTED – PLATFORM OVER-
LOADED.”

When the platform is overloaded,
report the "DRIVE & BOOM PRE-
VENTED – PLATFORM OVER-
LOADED."

Clarifications:
1. The term Report Fault is defined as logging the DTC on the Analyzer fault stack and flashing the System Distress lamp.
2. When specified, Ground Alarm energization shall only occur if MACHINE SETUP

 GROUND ALARM ≠ NO.

3. This selection is not Analyzer configurable in MACHINE SETUP

 LOAD SYSTEM but is shown here for completeness of the response table.