SECTION 6 - JLG CONTROL SYSTEM

6-22

– JLG Lift –

3121287

FUEL CUTOUT:

8*

1

2

3

4

ONE RESTART: One restart with limited run time when near Empty.

ENGINE STOP: No starting permitted when near Empty.

NONE

RESTART: Restarts allowed with limited run time when near Empty

4

* This menu item is visible only if Engine = Kubota D1105

TILT:

9*

1

2

3

4

5

6

5 DEGREES: Reduces the maximum speed of all boom functions to creep when tilted more than 5 degrees
and above elevation; also reduces drive speed to creep.

4 DEGREES: Reduces the maximum speed of all boom functions to creep when tilted more than 4 degrees
and above elevation; also reduces drive speed to creep.

3 DEGREES: Reduces the maximum speed of all boom functions to creep when tilted more than 3 degrees
and above elevation; also reduces drive speed to creep.

5 DEGREES + CUT: Reduces the maximum speed of all boom functions to creep when tilted more than 5
degrees and above elevation; also disallows tower lift up, drive, telescope out and lift up.

4 DEGREES + CUT: Reduces the maximum speed of all boom functions to creep when tilted more than 4
degrees and above elevation; also disallows tower lift up, drive, telescope out and lift up.

3 DEGREES + CUT: Reduces the maximum speed of all boom functions to creep when tilted more than 3
degrees and above elevation; also disallows tower lift up, drive, telescope out and lift up.

1

* Certain market selections will limit tilt options and alter default setting.
Note: Any of the selections above will light the tilt lamp when a tilted condition occurs and will sound the platform alarm when the machine is also above elevation.

JIB:

10*

1

2

NO: No jib installed.

YES: Jib installed which has up and down movements only.

2

* This menu item not visible.

4 WHEEL STEER:

11*

1

2

NO: No four-wheel steer installed.

YES: Four-wheel steer installed.

1

* This item not visible.

SKYGUARD:

12

1

2

NO: No SkyGuard system installed.

SKYGUARD: SkyGuard system installed.

1

GEN SET/WELDER:

13

1

2

No generator installed

BELT DRIVE: Belt driven setup.

1

GEN SET CUTOUT:

14*

1

2

MOTION ENABLED: Motion enabled when generator is ON.

MOTION CUTOUT: Motion cutout in platform mode only.

1

* Only visible if Gen Set / Welder = Belt Drive.

Table 6-2. Machine Configuration Programing Information

Configuration Label/Digit

Number

Description

Default

Number