3.11 COLD START SYSTEM

The JLG Control System monitors the engine coolant and
ambient temperature to determine cylinder preheating
requirements. If the coolant temperature is below 65° C when
control power is turned on, the glow plugs will be automati-
cally activated for a period of time based on the ambient tem-
perature up to a maximum of 20 seconds. During this preheat
period, the glow plug indicators on the control consoles will
flash. The operator should wait for the glow plugs to complete
their cycle before cranking the engine.

3.12 ENGINE OPERATING STATES

The Engine Operating State is determined by the Ground
Module. There are four different Engine Operating States
which include;

• Engine Stopped

• Engine Cranking

• Engine Starting

• Engine Running

ENGINE

STOPPED

ENGINE

RUNNING

ENGINE

CRANKING

ENGINE

STARTING

(RPM greater than 800 for 1/4 second)

(RPM greater than
800 for 1/4 second)

(RPM = 0 for 1/2 second)

(RPM = 0 for 1/2 second)

(Engine RPM = 0)

(RPM greater than 800 for 1/4 second)

(Engine Starter Not Engaged
& Engine RPM greater than 0)

(Engine Starter Engaged

& Engine RPM greater than 0)

Figure 3-38. Engine Operating State Diagram