Pressure limiter valve adjustment -37, Pressure limiter settings -37 – JLG 24RS Service Manual User Manual

Page 161

Advertising
background image

SECTION 5 - HYDRAULICS

3121287

– JLG Lift –

5-37

2.

Start the prime mover and operate at normal speed.

3.

Use a 17mm wrench to loosen the locking nut (L024).

4.

Activate the control input until pressure in the high side
of the system loop stops rising. This pressure is the PL
setting.

NOTE:

The model code on the serial plate gives the factory setting
of the PL (Pressure Limiter). The PL setting is referenced to
charge pressure. Subtract charge pressure from system
pressure gauge readings to compute the effective PL set-
ting.

5.

Return the pump to neutral and adjust the PL setting
using an internal hex wrench. Wrench size is in the dia-
gram on the previous page. Turn the adjusting screw
clockwise to increase the PL setting, counter clockwise
to decrease it. The adjustment is very sensitive. Change
per turn is approximately 150 bar [2176 psi].

NOTE:

Change per turn is 150 bar/rev [2176 psi/rev].

6.

Repeat steps four and five until you reach the desired PL
setting. After adjustment, torque the locknut (L024) to
12 N•m [9 lbf•ft]. Do not over torque.

7.

Shut down the prime mover. Remove gauges and
replace plugs.

Figure 5-34. Pressure Limiter Valve Adjustment

Table 5-9. Pressure Limiter Settings

Pressure Limiter Setting

HPRV setting

150

200

180

230

200

250

230

280

250

300

280

330

300

350

330

380

350

400

380

420

400

450

410

420

430

480

440

450

460

510

470

480

Table 5-9. Pressure Limiter Settings