2 personalities, Personalities – JLG 4017PS Service Manual User Manual

Page 165

Advertising
background image

9-7

3706PS, 3707PS, 4014PS, 4017PS, 33.7, 37.6, 37.7

Electrical System

9.5.2

Personalities

Fan Reverse
Timer: 2sec

2sec To 10sec

Access Level
1, 2, or 3;
Hydraulic
Variable
Speed Fan or
Reversing Fan
configured

Sets the length of time that the fan will be reversed
(cycling or demand)

Fan Reverse
Interval: 20min

5min To 60min

Sets the interval between cycling fan reversals

Tyre Selection:

Access Level
1, 2, or 3

Selects the tyre fitted for proper vehicle speed calibration
(refer to Vehicle Speed Calculation)

Default Gear
Selection: 2

1, 2, 3, 4

Access Levels
1,2,3

Sets the default transmission gear at power-up

ECM Service
Tool Access?

ECM Tool
Access?
Yes: Enter,
No: ESC

Access Level 1

When YES, the UGM shall not transmit CANbus
messages. This will allow maximum bandwidth for Deutz
service tools during re-programming. Power cycle is
required to resume normal operation.

Function

Description

Default Value

Main Lift

Allows the owner to adjust the Max Lift Up and Max Lift Down
function speeds

1400 mA (up)

1600 mA (down)

Soft Lift

Allows the owner to adjust the derate value when the boom
enters the soft lift zone

40%(3706PS, 33.7 & 37.6)

45% (3707PS & 37.7)

35% (4014PS & 4017PS)

Telescope

Allows the owner to adjust the Max Tele In and Max Tele Out
function speeds

1300 mA

Fork Tilt

Allows the owner to adjust the Max Fork Tilt Up and Max Fork
Tilt Down function speeds

1150 mA

Platform Level

Allows the owner to adjust the Max Platform Level Up and Max
Platform Level Down function speeds

800 mA

Platform Rotate

Allows the owner to adjust the Max Platform Left and Max
Platform Right function speeds

1000 mA

Platform Lift

Allows the owner to adjust the Max Platform Lift Up and Max
Platform Lift Down function speeds

1020 mA (up)

960 mA (down)

Platform
Telescope

Allows the owner to adjust the Max Platform Tele In and Max
Platform Tele Out function speeds

1000 mA (in)

1080 mA (out)

Outriggers

Allows the owner to adjust the Max Outrigger Up and Max
Outrigger Down function speeds

1000 mA

Frame Level

Allows the owner to adjust the Max Frame Level Left and Max
Frame Level Right function speeds

1000 mA

Bucket Lift

Allows the owner to adjust the Max Bucket Up and Max Bucket
Down function speeds

1400 mA (up)

1600 mA (down)