Electrical system – JLG 4017PS Service Manual User Manual

Page 214

Advertising
background image

Electrical System

9-56

3706PS, 3707PS, 4014PS, 4017PS, 33.7, 37.6, 37.7

HYDRAULIC

FILTER

RESTRICTION

2332

5000mS

Ten minutes after power-up, UGM

J2-24 Hydraulic Filter Restriction

Switch digital input is grounded for

3,000mS

UGM J2-24

Hydraulic

Filter

Restriction

Switch digital

input is not

grounded for

1,000mS

ALL WHEEL STEER

INPUT – INVALID

SIGNAL

2333

5000mS

All Wheel Steer Mode Switch is

ignored

UGM J4-35 All Wheel Steer digital

input is energized at power up or for

7,000mS

Power cycled

CRAB STEER

INPUT – INVALID

SIGNAL

2334

5000mS

Crab Steer Mode Switch is ignored

UGM J4-34 Crab Steer digital input

is energized at power up or for

7,000mS

Power cycled

JOYSTICK LOCK

INPUT – INVALID

SIGNAL

2335

5000mS

Joystick Lock Switch is ignored

Machine Setup’s MARKET is CE or

AUSTRALIA; UGM J7-11 Joystick

Lock digital input is energized at

power up or for 7,000mS

Power cycled

LOAD MOMENT

SHUTOFF INPUT –

INVALID SIGNAL

2336

5000mS

Load Moment Shutoff Switch is

ignored

Machine Setup’s MARKET is CE or

AUSTRALIA; UGM J4-33 Load

Moment Shutoff digital input is

energized at power up or for 40

Seconds

Power cycled

BUCKET MODE

INPUT – INVALID

SIGNAL

2337

5000mS

Bucket Mode Switch is ignored

Fork Tilt Mode is engaged

UGM J4-19 Bucket Mode digital

input is energized at power up or for

7,000mS

Power cycled

2–WHEEL STEER

INPUT – INVALID

SIGNAL

2338

5000mS

2-Wheel Steer Switch is ignored

UGM J3-9 2-Wheel Steer digital

input is energized at power up or for

7,000mS

Power cycled

KEYPAD OK

BUTTON – INVALID

SIGNAL

2339

5000mS

Keypad OK button is ignored

The keypad OK button is closed at

power up or for 7,000mS

Power cycled

KEYPAD CANCEL

BUTTON – INVALID

SIGNAL

2340

5000mS

Keypad Cancel button is ignored

The keypad Cancel button is closed

at power up or for 7,000mS

Power cycled

KEYPAD UP

BUTTON – INVALID

SIGNAL

2341

5000mS

Keypad Up button is ignored

The keypad Up button is closed at

power up or for 7,000mS (except in

Analyzer Mode)

Power cycled

KEYPAD DOWN

BUTTON – INVALID

SIGNAL

2342

5000mS

Keypad Down button is ignored

The keypad Down button is closed

at power up or for 7,000mS (except

in Analyzer Mode)

Power cycled