Electrical system – JLG 4017PS Service Manual User Manual

Page 210

Advertising
background image

Electrical System

9-52

3706PS, 3707PS, 4014PS, 4017PS, 33.7, 37.6, 37.7

PLATFORM

LEVEL UP

PREVENTED –

INPUT HIGH AT

POWER UP

2114

5000mS

Platform Level Up & Down are

prevented

Machine Setup’s PLATFORM

OPTION is ENABLED; Platform

Mode; PLT J1-9 Platform Level Up

Switch is closed at power-up

Power cycled

PLATFORM

LEVEL DOWN

PREVENTED –

INPUT HIGH AT

POWER UP

2115

5000mS

Platform Level Up & Down are

prevented

Machine Setup’s PLATFORM

OPTION is ENABLED; Platform

Mode; PLT J1-10 Platform Level

Down Switch is closed at power-up

in platform mode

Power cycled

APU SWITCH

INPUT INVALID –

INPUT HIGH AT

POWER UP

2116

5000mS

APU functionality is prevented

Lift Up is prevented above +10°

Telescope Out is prevented once

the boom is fully retracted

Machine Setup’s PLATFORM

OPTION is ENABLED; Platform

Attached; PLT J4-16 APU Enable

Switch is closed at power-up

The switch is

open

momentarily

(1,000mS)

PLATFORM

JOYSTICK NOT IN

NEUTRAL

POSITION AT

POWER UP

2117

5000mS

Main Lift and Telescope functions

are prevented

Machine Setup’s PLATFORM

OPTION is ENABLED; Platform

Mode; platform joystick is not in

neutral position at power-up

The platform

joystick

returns to the

neutral

position

ENGINE PRE-

HEAT

PREVENTED –

INPUT HIGH AT

POWER UP

2118

5000mS

Engine pre-heat is prevented

Cabin Mode is active; UGM J4-20

Engine Pre-Heat is energized at

power-up

Machine Setup’s PLATFORM

OPTION is ENABLED; Platform

Mode is active; PLG J1-23 Engine

Pre-Heat is energized at power-up

The switch is

open

momentarily

(1,000mS)

FRAME LEVEL

RIGHT INPUT –

INVALID SIGNAL

2119

5000mS

Frame Level Left & Right are

prevented

Machine Setup’s MODEL is 4014 or

4017 and the UGM J4-17 Frame

Leveling Right Switch is closed at

power-up

Power cycled

FRAME LEVEL

LEFT INPUT –

INVALID SIGNAL

2120

5000mS

Frame Level Left & Right are

prevented

Machine Setup’s MODEL is 4014 or

4017 and the UGM J4-9 Frame

Leveling Left Switch is closed at

power-up

Power cycled

HYDRAULIC

QUICK CONNECT

INPUT – INVALID

SIGNAL

2121

5000mS

Hydraulic Quick Connect is

prevented

Machine Setup’s HYDRAULIC

QUICK CONNECT is YES; UGM

J7-35 Hydraulic Quick Connect On

is high at power-up

Machine Setup’s HYDRAULIC

QUICK CONNECT is YES; UGM

J3-10 Hydraulic Quick Connect Off

is low at power-up

Machine Setup’s HYDRAULIC

QUICK CONNECT is YES; UGM

J7-35 Hydraulic Quick Connect On

and UGM J3-10 Hydraulic Quick

Connect Off are the same state for

500mS

Power cycled

CONTINUOUS

AUXILIARY

HYDRAULICS

SWITCH HIGH AT

POWER UP

2122

5000mS

Continuous Auxiliary Hydraulics are

prevented

The cabin joystick’s S switch is

closed at power-up

The switch is

open

momentarily

(1,000mS)