JLG 4017PS Service Manual User Manual

Page 249

Advertising
background image

9-91

3706PS, 3707PS, 4014PS, 4017PS, 33.7, 37.6, 37.7

Electrical System

883

523633

11

7-0-1

Nox conversion rate insufficient (SCR-Cat defect, bad Ad Blue
quality); temperature range 2

887

3234

11

8-0-7

Nox Sensor downstream of SCR Catalysator;
plausibility error "stuck in range"

889

3224

1

8-0-8

Nox sensor upstream of SCR Catalysator; low signal not plausible

892

4345

11

8-7-0

Sensor backflow line pressure (SCR); plausibility error

893

4343

11

8-7-1

General pressure check error (SCR)

894

4374

13

8-7-2

Pressure stabilization error dosing valve (SCR)

896

523723

11

8-7-4

Detection of Ad Blue filled SCR system in Init-State

897

523632

16

8-7-5

Pump pressure SCR metering unit too high

898

523632

18

8-7-6

Pump pressure SCR metering unit too low

899

523632

0

8-7-7

Pressure overload of SCR-System

900

523632

1

8-7-8

Pressure build-up error SCR-System

903

4365

0

8-8-1

Urea tank temperature too high

905

3241

0

8-8-3

Sensor SCR catalyst upstream temperature too high; plausibility
error

906

3241

1

8-8-4

Sensor SCR catalyst upstream temperature too low; plausibility
error

908

3361

7

8-8-6

Ad Blue dosing valve blocked (SCR)

914

523720

2

6-9-0

Sensor urea supply module heater temperature;
plausibility error (normal condition)

915

523720

2

6-9-0

Sensor urea supply module heater temperature;
plausibility error (cold start condition)

916

523721

2

6-8-9

Sensor urea supply module temperature;
plausibility error (normal condition)

917

523721

2

6-8-9

Sensor urea supply module temperature;
plausibility error (cold start condition)

919

523330

14

1-3-1

Immobilizer status; fuel blocked

925

523720

8

6-9-0

Urea supply module heater temperature; duty cycle in failure range

926

523720

8

6-9-0

Urea supply module heater temperature; duty cycle in invalid range

927

523721

11

6-8-9

Urea supply module temperature measurement not available

928

523722

8

6-9-1

Urea supply module PWM signal; period outside valid range

929

523722

8

6-9-1

Detect faulty PWM signal from Supply Module

Advertising