Electrical system – JLG 4017PS Service Manual User Manual

Page 227

Advertising
background image

9-69

3706PS, 3707PS, 4014PS, 4017PS, 33.7, 37.6, 37.7

Electrical System

f.

Battery Supply (44X)

AIR FILTER

RESTRICTION

4321

5000mS

The engine has been running for at
least 7,000mS, and UGM J1-34 Air

Filter Restriction digital input is

LOW

UGM J1-34

Air Filter

Restriction

input is high

for 1,000mS

LOSS OF

ENGINE SPEED

SIGNAL

4322

5000mS

Engine Start is prevented

Continuous Auxiliary Hydraulics is

forced to 0% (cancelled)

Electronic Engine is configured

and the ECM reports a loss of

engine speed signal via DM1

(190:8)

Power cycled

BATTERY

SUPPLY

44XXX

-

-

-

-

BATTERY

VOLTAGE TOO

LOW – SYSTEM

SHUTDOWN

441

-

·

Hydraulic functions are

prevented

·

All digital outputs are disabled

·

Platform Indicators are

disabled

·

UGM detects the battery

voltage is < 9V for at least
500mS; engine is not cranking

·

Machine Setup’s

PLATFORM OPTION is
ENABLED; PLT detects the
battery voltage is < 9V for at least
250mS; engine is not cranking

Power cycled

BATTERY

VOLTAGE TOO

HIGH – SYSTEM

SHUTDOWN

442

-

·

Hydraulic functions are

prevented

·

All digital outputs are disabled

·

UGM detects the battery

voltage > 16V for at least 250mS

·

Machine Setup’s

PLATFORM OPTION is

ENABLED; PLT detects the

battery voltage is >16V for at

least 250mS

Power cycled

LSS BATTERY

VOLTAGE TOO

HIGH

443

Continuously

Platform assumed to be overloaded

Load Sensing System is

configured; platform attached;

engine is not cranking; LSS

Module reports BATT TOO HIGH

Power cycled

LSS BATTERY

VOLTAGE TOO

LOW

444

Continuously

Platform assumed to be overloaded

Load Sensing System is

configured; platform attached;

engine is not cranking; LSS

Module reports BATT TOO LOW

Power cycled

BATTERY

VOLTAGE LOW

445

5000mS

UGM detects battery voltage <

11V for 3,000mS, and the engine

is running

UGM detects

battery voltage

>11V for

10,000mS

REFERENCE

VOLTAGE OUT

OF RANGE –

GROUND

447

5000mS

Hydraulic functions are prevented

UGM detects its reference

voltage is out of range (>5.4V or

<4.6V) for 1000mS.

Power cycled

REFERENCE

VOLTAGE OUT

OF RANGE –

PLATFORM

448

5000mS

Hydraulic functions are prevented

Machine Setup’s PLATFORM

OPTION is ENABLED; PLT

detects its reference voltage is

out of range (>5.4V or <4.6V) for

1000mS.

Power cycled