JLG 4017PS Service Manual User Manual

Page 248

Advertising
background image

Electrical System

9-90

3706PS, 3707PS, 4014PS, 4017PS, 33.7, 37.6, 37.7

833

523009

10

2-5-3

Pressure relief valve (PRV) reached maximum allowed open time

838

523450

3

1-4-3

Multiple Stage Switch constant speed; short circuit to battery

839

523450

4

1-4-3

Multiple Stage Switch constant speed; short circuit to ground

840

523450

2

1-4-3

Multiple Stage Switch constant speed; plausibility error

841

523451

3

1-4-3

Multiple Stage Switch engine speed control parameter; short circuit
to battery

842

523451

4

1-4-3

Multiple Stage Switch engine speed control parameter; short circuit
to ground

843

523451

2

1-4-3

Multiple Stage Switch engine speed control parameter; plausibility
error

844

523452

3

1-4-3

Multiple Stage Switch engine torque limitation curve; short circuit to
battery

845

523452

4

1-4-3

Multiple Stage Switch engine torque limitation curve; short circuit to
ground

846

523452

2

1-4-3

Multiple Stage Switch engine torque limitation curve; plausibility
error

856

523613

0

1-3-4

Maximum positive deviation of rail pressure exceeded (RailMeUn0)

857

523613

0

1-3-4

Maximum positive deviation of rail pressure in metering unit
exceeded (RailMeUn1)

858

523613

0

1-3-4

Rail system leakage detected (RailMeUn10)

859

523613

0

1-3-4

Maximum negative deviation of rail pressure in metering unit
exceeded (RailMeUn2)

860

523613

0

1-3-4

Negative deviation of rail pressure second stage (RailMeUn22)

861

523613

1

1-3-4

Minimum rail pressure exceeded (RailMeUn3)

862

523613

0

1-3-4

Maximum rail pressure exceeded (RailMeUn4)

864

523613

2

1-3-4

Set point of metering unit in overrun mode not plausible

876

523470

7

1-4-6

Maximum rail pressure in limp home mode exceeded (PRV)

877

157

3

1-4-7

Sensor error rail pressure; signal range check high

878

157

4

1-4-7

Sensor error rail pressure; signal range check low

881

523633

11

7-0-1

Nox conversion rate insufficient (SCR-Cat defect, bad Ad Blue
quality)

882

523633

11

7-0-1

Nox conversion rate insufficient (SCR-Cat defect, bad Ad Blue
quality); temperature range 1