9-67

3706PS, 3707PS, 4014PS, 4017PS, 33.7, 37.6, 37.7

Electrical System

ALL WHEEL

STEER VALVE –

SHORT TO

GROUND

33275

5000mS

Short to ground is detected on

UGM J2-4

Power cycled

APU PUMP RELAY

– OPEN CIRCUIT

33276

5000mS

APU functionality is prevented

Machine Setup’s PLATFORM

OPTION is ENABLED; open-circuit

is detected on UGM J1-13

Power cycled

APU PUMP RELAY

– SHORT TO

BATTERY

33277

Continuously

APU functionality is prevented

Machine Setup’s PLATFORM

OPTION is ENABLED; short to

battery is detected on UGM J1-13

Power cycled

APU PUMP RELAY

– SHORT TO

GROUND

33278

5000mS

APU functionality is prevented

Machine Setup’s PLATFORM

OPTION is ENABLED; short to

ground is detected on UGM J1-13

Power cycled

ENGAGE

STARTER

OUTPUT – OPEN

CIRCUIT

33282

5000mS

Open-circuit is detected on UGM

J2-26

Power cycled

ENGAGE

STARTER

OUTPUT – SHORT

TO BATTERY

33283

Continuously

Engage Starter digital output

prevented

Energize ECM / Fuel Relay digital

output (to stop engine)

Short to battery is detected on

UGM J2-26

Power cycled

ENGAGE

STARTER

OUTPUT – SHORT

TO GROUND

33284

5000mS

Engage Starter digital output

prevented

Short to ground is detected on

UGM J2-26

Power cycled

ALTERNATOR

EXCITATION LINE

– SHORT TO

BATTERY

33285

5000mS

Alternator Excitation digital output is

prevented

UGM J4-7 Alternator D+ is

energized 2,000mS after engine

has stopped

Power cycled

LIFT – CURRENT

FEEDBACK

READING TOO

LOW

33287

5000mS

Actual lift up / down (UGM J3-2) &

commanded current disagree by

>125mA when command is >250

mA for 1000mS

Actual lift up / down current <

225mA and PWM is >40% for

100ms

Power cycled

TELESCOPE –

CURRENT

FEEDBACK

READING TOO

LOW

33288

5000mS

Actual telescope in / out (UGM J3-

4) & commanded current disagree

by >125mA when command is

>250 mA for 1000mS

Actual telescope in / out current <

225mA and PWM is >40% for

100ms

Power cycled

STABILIZERS/

FRAME LEVEL –

CURRENT

FEEDBACK

READING TOO

LOW

33289

5000mS

Actual stabilizer / frame leveling

(UGM J3-6) & commanded current

disagree by >125mA when

command is >250 mA for 1000mS

Actual stabilizer / frame leveling

current < 225mA and PWM is

>40% for 100ms

Advertising