JLG 4017PS Service Manual User Manual

Page 167

Advertising
background image

9-9

3706PS, 3707PS, 4014PS, 4017PS, 33.7, 37.6, 37.7

Electrical System

Calibrations:
Boom Angle

Calibrate Boom
Angle Sensor?

Access Levels
1,2;
Platform Not
Attached

Used by technicians to calibrate the boom angle
sensor; press ENTER to confirm; ESC to exit

Press Enter At
Lowest Position.

Technician must lower boom to mechanical stop, press
ENTER to confirm

Boom Angle:
Calibrating...

Displayed while control system averages readings

Lift Up. Press
Enter At Top.

Technician must raise boom to mechanical stop, press
ENTER to confirm.

Boom Angle:
Calibrating...

Displayed while control system averages readings

Calibration:
Complete

Calibration was successful; press ESC key to exit

Calibration:
Remove Platform

The platform was attached when the calibration was
initiated; press ESC key to exit

Calibration:
Failed

The minimum or maximum boom angle sensor counts
were improper for this vehicle; press ESC key to exit;
press LEFT or RIGHT for the BOOM ANGLE RAW
COUNTS display

Calibration:
Sensor Fault

DTC 2344, 2345, 2346, 2353, or 6621 was active and
calibration could not succeed; press ESC key to exit;
press LEFT or RIGHT for the BOOM ANGLE RAW
COUNTS display

Boom Angle Raw:
Counts: xxxx

Access Levels
1,2;
Machine Setup’s
MODEL is
4014PS or
4017PS; platform
is not attached

Displays the raw ADC counts for the CANbus boom
angle sensor after a SENSOR FAULT or FAILED event

Boom Angle Raw:
Counts: xxxx

Access Levels
1,2;
Machine Setup’s
MODEL is
3706PS or
3707PS

Displays the raw ADC counts for the boom angle
sensor from UGM J7-4 after a SENSOR FAULT or
FAILED event

Advertising
This manual is related to the following products: