Electrical system – JLG 4017PS Service Manual User Manual

Page 212

Advertising
background image

Electrical System

9-54

3706PS, 3707PS, 4014PS, 4017PS, 33.7, 37.6, 37.7

b. Cabin Controls (23X)

ENGINE START

PREVENTED –

FUNCTION

ENABLE SWITCH

ENGAGED

2229

5000mS

Engine Start is prevented

Platform Mode; Function Enable

Switch is engaged; Engine Start

Switch (PLT J1-14) is closed

Function

Enable Switch

is not

engaged;

Engine Start

Switch is open

PLATFORM

JOYSTICK – OUT

OF RANGE HIGH

2230

5000mS

Main Lift Up, Lift Down, Telescope

In, and Telescope Out are

prevented

Platform Mode; PLT J5-3 Main Lift

Joystick wiper is out of range

Platform Mode; PLT J5-4 Main

Telescope Joystick wiper is out of

range

Power cycled

PLATFORM

JOYSTICK –

CENTER TAP BAD

2231

5000mS

Main Lift Up, Lift Down, Telescope

In, and Telescope Out are

prevented

Platform Mode; PLT J5-2 Platform

Lift Joystick center tap is out of

range

Platform Mode; PLT J5-5 Platform

Telescope Joystick center tap is out

of range

Power cycled

FUNCTION

ENABLE RELAY –

INVALID SIGNAL

2233

Continuously

PLT J2-19 Function Enable Relay

shall be de-energized

Engine Start is prevented

Platform controls are prevented

Platform Mode; power-up; PLT J7-

8 Function Enable Switch is

energized or PLT J2-4 Function

Integrity Signal is de-energized

Platform Mode; 600mS after PLT

J2-19 Function Enable Relay is

energized; PLT J7-8 Function

Enable Switch is de-energized or

PLT J2-4 Function Integrity Signal

is energized

Power cycled

HELP MESSAGE

DTC

CABIN

ALARM

ACTIONS

TRIGGER

LATCH

CONDITION

OPERATING MODE

INTERLOCK –

SHIFTER NOT IN

NEUTRAL

239

5000mS

Engine Start is prevented

Platform controls are prevented

Transition from Cabin to Platform

Mode; cabin joystick’s FNR switch is

reported as Forward or Reverse

Cabin

joystick’s FNR

switch is set

to Neutral

PLATFORM

OPTION NOT

CONFIGURED

2311

Continuously

Platform controls shall be

prevented

Machine Setup’s PLATFORM

OPTION is DISABLED;

UGM J1-21 Platform Attached is

grounded, Platform Module CANbus

is detected, or key switch is in

Platform Mode

Power cycled

OPERATING

STATION

SELECTION

INVALID

2314

Continuously

Hydraulic functions are prevented

Direction selection shall be neutral

UGM J7-3 Ground Mode and UGM

J7-2 Platform Mode are both high

Power cycled

OPERATING MODE

INTERLOCK –

STABILIZERS NOT

DEPLOYED

2315

5000mS

Lift Up and Telescope Out are

prevented when the boom angles

is greater than +10° (after power-

up)

Lift Down is prevented when the
boom angle is greater than +10°

and the Boom Retracted Switch is

open (not fully retracted; after

power-up)

Key switch

Platform; Stabilizer Deployed 1

Switch is not deployed

Key switch Platform; Stabilizer

Deployed 2 Switch is not deployed

Stabilizer

Deployed

1 and 2 are

deployed

Advertising
This manual is related to the following products: