9-53

3706PS, 3707PS, 4014PS, 4017PS, 33.7, 37.6, 37.7

Electrical System

a. Platform Controls (22X)

JOYSTICK

TRIGGER SWITCH

ACTIVE AT

POWER UP

2123

5000mS

The cabin joystick trigger is

prevented (Stabilizers, Boom Float)

The cabin joystick’s trigger is

pressed at power-up

The push

button is
released
(150mS)

JOYSTICK LEFT
ROLLER NOT IN

THE NEUTRAL

POSITION AT

POWER UP

2124

5000mS

The ARF roller is prevented (Fork

Tilt or Telescope)

The cabin joystick’s left roller (ARF)

is not neutral at power-up

The roller
returns to

neutral

(150mS)

JOYSTICK RIGHT

ROLLER NOT IN

THE NEUTRAL

POSITION AT

POWER UP

2125

5000mS

The ARR roller is prevented

(Auxiliary Hydraulics, Hydraulic

Quick Connect)

The cabin joystick’s right roller

(ARR) is not neutral at power-up

The roller
returns to

neutral

(150mS)

BOOM RIDE

ENABLE SWITCH

NOT IN THE OFF

POSITION AT

POWER UP

2130

5000mS

Boom Ride is prevented

Machine Setup’s BOOM RIDE is

YES; AM J1-3 Boom Ride Switch is

closed at power-up

The switch is

open

momentarily

(500mS)

HELP MESSAGE

DTC

CABIN

ALARM

ACTIONS

TRIGGER

LATCH

CONDITION

PLATFORM LEVEL

– CONFLICTING
INPUT SIGNALS

2225

5000mS

Platform Level Up & Down are

prevented

Platform Mode; PLT J1-9 Platform

Level Up Switch and PLT J1-10

Platform Level Down Switch are

closed at the same time

Power cycled

PLATFORM

ROTATE –

CONFLICTING

INPUT SIGNALS

2226

5000mS

Platform Rotate Left & Right are

prevented

Platform Mode; PLT J1-8 Platform

Rotate Left Switch and PLT J1-7

Platform Rotate Right Switch are

closed at the same time

Power cycled

FUNCTION

ENABLE

INTERLOCK –

ENABLE SWITCH

NOT SELECTED

FIRST

2227

5000mS

Platform controls are prevented

Platform Mode; Function Enable

Switch is engaged after any of the

following:

Platform Level Down Switch (PLT

J1-10) is closed

Platform Rotate Left Switch (PLT

J1-8) is closed

Platform Rotate Right Switch (PLT

J1-7) is closed

Platform Lift Joystick (PLT J5-3) is

not neutral

Platform Telescope Joystick (PLT

J5-4) is not neutral

The platform

switch is

opened and
the platform

joystick

returns neutral

FUNCTION

ENABLE

INTERLOCK – NOT

SELECTED IN

TIME

2228

-

Platform controls are prevented

Platform Mode; Function Enable

Switch is engaged (PLT J7-8

Function Enable Switch is open;

UGM J7-15 Function Enable

Switch is closed); 7,000mS expired

before a hydraulic function was

activated

Function

Enable Switch

is not

engaged

Advertising