Electrical system – JLG 4017PS Service Manual User Manual

Page 226

Advertising
background image

Electrical System

9-68

3706PS, 3707PS, 4014PS, 4017PS, 33.7, 37.6, 37.7

e. Engine (43X)

FORK TILT –

CURRENT

FEEDBACK

READING TOO

LOW

33290

5000mS

Actual fork tilt up / down (UGM J3-

6) & commanded current disagree

by >125mA when command is

>250 mA for 1000mS

Actual fork tilt up / down current <

225mA and PWM is >40% for

100ms

Power cycled

AUXILIARY

HYDRAULICS –

CURRENT

FEEDBACK

READING TOO

LOW

33291

5000mS

Actual auxiliary function A / B

(UGM J3-14) & commanded

current disagree by >125mA when

command is >250 mA for 1000mS

Actual auxiliary A / B current <

225mA and PWM is >40% for

100ms

Power cycled

BOOM RIDE

VALVE – SHORT

TO BATTERY OR

OPEN CIRCUIT

33369

Continuously

Boom Ride is prevented

Machine Setup’s BOOM RIDE is

YES; short to battery or open-

circuit is detected on AM J1-7

Power cycled

BOOM RIDE

VALVE – SHORT

TO GROUND

33338

5000mS

Boom Ride is prevented

Machine Setup’s BOOM RIDE is
YES; short to ground is detected

on AM J1-7

Power cycled

BOOM FLOAT

VALVE – SHORT

TO BATTERY OR

OPEN CIRCUIT

33370

Continuously

Boom Ride is prevented

Boom Float is prevented

Main Lift Up is prevented

Machine Setup’s BOOM FLOAT is

YES; short to battery or open-

circuit is detected on AM J1-9

Power cycled

BOOM FLOAT

VALVE – SHORT

TO GROUND

33341

5000mS

Boom Float is prevented

Main Lift Up is prevented

Machine Setup’s BOOM FLOAT is

YES; short to ground is detected

on AM J1-9

Power cycled

BOOM TANK

VALVE – SHORT

TO BATTERY OR

OPEN CIRCUIT

33371

Continuously

Boom Ride is prevented

Boom Float is prevented

Main Lift Up is prevented

Machine Setup’s BOOM FLOAT is

YES; short to battery or open-

circuit is detected on AM J1-8

Power cycled

BOOM TANK

VALVE – SHORT

TO GROUND

33344

5000mS

Boom Ride is prevented

Boom Float is prevented

Machine Setup’s BOOM FLOAT is

YES; short to ground is detected

on AM J1-8

Power cycled

ENGINE

43XXX

-

-

-

-

ENGINE

TROUBLE CODE:

(SPN:FMI)

437

Continuously

The Electronic Engine’s ECM

detects a fault condition and

transmits a DM1 message

Power cycled

LOW ENGINE

OIL PRESSURE

WARNING

4318

Continuously

Electronic Engine is configured

and SPN100:FMI17 or

SPN100:FMI18 is active

Power cycled

LOW ENGINE

OIL PRESSURE

CRITICAL

4319

Continuously

Electronic Engine is configured

and SPN100:FMI1 is active

Power cycled