Electrical System

9-58

3706PS, 3707PS, 4014PS, 4017PS, 33.7, 37.6, 37.7

SYSTEM

INTERLOCK – SET
JOYSTICK INPUTS

TO NEUTRAL

2347

-

The cabin joystick’s X-Axis, Y-

Axis, ARL roller, and ARR roller

are prevented

Engine is running, cabin mode, the

cabin joystick is not neutral, and one

of the following situations occurs.

Hydraulic Quick Connect

functionality is activated or de-

activated

Auxiliary Pressure Release (S

Switch) is closed but the function is

not activated

Bucket mode is active and Platform

becomes attached or coupled

BUCKET MODE INPUT – INVALID

SIGNAL (2337) fault becomes

active

Joystick Lock is initiated

CANBUS FAILURE – CABIN

JOYSTICK (6617) fault becomes

active

Entire cabin

joystick is

neutral

momentarily

ENGINE START

INPUT – INVALID

SIGNAL

2348

5000mS

Engine Start is prevented

UGM J4-8 Engine Start digital input

energized after the engine is

running for more than 7,000mS

The switch is

open

momentarily

(1,000mS)

LIFT ANGLE

DERATED –

STABILIZERS NOT

DEPLOYED

2349

5000mS

Lift Up is prevented

Machine Setup’s MODEL is 4017;

Cabin Mode;

at least one Stabilizer is not

deployed; platform is not attached;

Lift Up attempted; boom angle >

+60°

Stabilizer 1

and 2 are

deployed

(250mS)

CABIN JOYSTICK –

LEFT ROLLER

FAULT

2350

Continuously

Left Roller shall be prevented

(Fork Tilt / Telescope)

Cabin joystick transmits a DM1

(SPN:FMI) with 2662:14, 520210:3,

520210:4

Cabin joystick transmits Error (1:0)

for the Telescope / Tilt Roller

Neutral, Backward, or Forward

position

Cabin joystick transmits 1022 as the

Telescope / Tilt Roller position

Power cycled

CABIN JOYSTICK –

RIGHT ROLLER

FAULT

2351

Continuously

Right Roller shall be prevented

(Auxiliary Hydraulics)

Cabin joystick transmits a DM1

(SPN:FMI) with 2663:14, 520211:3,

520211:4

Cabin joystick transmits Error (1:0)

for the Auxiliary Roller Neutral,
Backward, or Forward position

Cabin joystick transmits 1022 as the

Auxiliary Roller position

Power cycled

CABIN JOYSTICK –

TRIGGER SWITCH

FAULT

2352

Continuously

Trigger shall be prevented (Boom

Float / Stabilizers)

Cabin joystick transmits Error (1:0)

for the Trigger switch

Power cycled