JLG 4017PS Service Manual User Manual

Page 253

Advertising
background image

9-95

3706PS, 3707PS, 4014PS, 4017PS, 33.7, 37.6, 37.7

Electrical System

1066

1180

11

5-5-6

Sensor exhaust gas temperature upstream turbine; plausibility
error

1067

1180

3

5-5-6

Sensor error exhaust gas temperature upstream turbine; signal
range check high

1068

1180

4

5-5-6

Sensor error exhaust gas temperature upstream turbine; signal
range check low

1069

4360

0

6-6-8

Physical range check high for urea catalyst upstream temperature

1070

4360

1

6-6-8

Physical range low for urea catalyst upstream temperature

1072

4360

3

6-6-8

Sensor error urea catalyst exhaust gas temperature upstream;
signal range check high

1073

4360

4

6-6-8

Sensor error urea catalyst exhaust gas temperature upstream;
signal range check low

1074

1761

14

6-7-0

Urea tank level; warning threshold exceeded

1077

3361

3

6-7-7

Urea dosing valve; short circuit to battery

1078

3361

3

6-7-7

Urea dosing valve high side; short circuit to battery

1079

3361

4

6-7-7

Urea dosing valve low side; short circuit to ground

1080

3361

4

6-7-7

Urea dosing valve high side; short circuit

1081

4345

5

6-7-4

SCR heater relay urea return line; open load

1082

523909

5

7-6-2

SCR main relay: cable break

1083

4343

5

6-7-3

SCR heater relay urea pressure line; open load

1084

4366

5

7-6-2

SCR main relay: shortcut to battery

1085

4366

5

7-6-2

SCR main relay: shortcut to ground

1086

4341

5

6-7-5

SCR-heater relay urea supply line; open load

1087

523719

5

6-7-2

SCR heater relay urea supply module; open load

1088

4366

5

6-7-1

Tank heating valve: open load

1089

4243

11

7-8-3

Urea pressure line heating procedure not successful; shut off
SCR-system

1090

4345

5

6-7-4

SCR-heater urea return line; open load

1092

4345

3

6-7-4

SCR-heater urea return line; short circuit to battery

1093

4345

4

6-7-4

SCR-heater urea return line; short circuit to ground

1094

4343

5

6-7-3

SCR-heater urea pressure line; open load

1096

4343

3

6-7-3

SCR-heater urea pressure line; short circuit to battery

1097

4343

4

6-7-3

SCR-heater urea pressure line; short circuit to ground

Advertising