Electrical system – JLG 4017PS Service Manual User Manual

Page 229

Advertising
background image

9-71

3706PS, 3707PS, 4014PS, 4017PS, 33.7, 37.6, 37.7

Electrical System

FAN SPEED

VALVE – SHORT

TO BATTERY OR

OPEN CIRCUIT

4620

5000mS

Hydraulic Fan Reversing is

prevented

Hydraulic Variable Speed Fan is

configured;

short to battery or open-circuit is

detected on TCM J2-11

for 1,000mS

Power cycled

FAN SPEED

VALVE – SHORT

TO GROUND

4621

5000mS

Hydraulic Fan Reversing is

prevented

Hydraulic Variable Speed Fan is

configured;

short to ground is detected on

TCM J2-11 at power-up

Power cycled

FAN REVERSE

VALVE – SHORT

TO BATTERY OR

OPEN CIRCUIT

4622

5000mS

·

Hydraulic Fan Reversing

is prevented

·

Reversing Fan is

prevented

·

Hydraulic Variable

Speed Fan is configured;
Machine Setup’s HYD FAN REV
is YES;
short to battery or open-circuit is
detected on TCM J2-12

·

for 1,000mS

·

Reversing Fan is

configured; short to battery or
open-circuit is detected on TCM
J2-12 for 1,000mS

Power cycled

FAN REVERSE

VALVE – SHORT

TO GROUND

4623

5000mS

·

Hydraulic Fan Reversing

is prevented

·

Reversing Fan is

prevented

·

Hydraulic Variable

Speed Fan is configured;
Machine Setup’s HYD FAN REV
is YES;
short to ground is detected on
TCM J2-12 at power-up
(momentarily energize digital
output if engine speed is zero)

·

Reversing Fan is

configured; short to ground is
detected on TCM J2-12 at
power-up

Power cycled

TRANSMISSION

REVERSE COIL –

SHORT TO

BATTERY OR

OPEN CIRCUIT

4628

Continuously

Direction Selection shall be Neutral

when Calibration’s TRANS

SERVICE is NO

Short to battery or open-circuit is

detected on TCM J5-5 for

1,000mS

Power cycled

TRANSMISSION

REVERSE COIL –

SHORT TO

GROUND

4629

Continuously

Direction Selection shall be Neutral

when Calibration’s TRANS

SERVICE is NO

Short to ground is detected on

TCM J5-5

Power cycled

TRANSMISSION

FWD LOW COIL –

SHORT TO

BATTERY OR

OPEN CIRCUIT

4630

Continuously

Direction Selection shall be Neutral

when Calibration’s TRANS

SERVICE is NO

Short to battery or open-circuit is

detected on TCM J5-3 for

1,000mS

Power cycled

TRANSMISSION

FWD LOW COIL –

SHORT TO

GROUND

4631

Continuously

Direction Selection shall be Neutral

when Calibration’s TRANS

SERVICE is NO

Short to ground is detected on

TCM J5-3

Power cycled