Electrical system – JLG 4017PS Service Manual User Manual

Page 235

Advertising
background image

9-77

3706PS, 3707PS, 4014PS, 4017PS, 33.7, 37.6, 37.7

Electrical System

FUNCTION

LOCKED OUT –

PLATFORM

MODULE

SOFTWARE

VERSION

IMPROPER

9910

Continuously

·Hydraulic functions are prevented in

Platform Mode

·Engine is shutdown

· in Platform Mode

·Engine Start is prevented

· in Platform Mode

Platform Module transmitted a Major

Software Version that was not 4

when Software Type (UGM & PLT)

is Production

Power cycled

FUNCTION

LOCKED OUT –

LSS MODULE

SOFTWARE

VERSION

IMPROPER

9911

Continuously

·Hydraulic functions are prevented in

Platform Mode

·Engine is shutdown

·Engine Start is prevented

· in Platform Mode

LSS Module transmitted a Major

Software Version that was not 7 or a
Minor Software Version less than 17

Power cycled

CHASSIS TILT

SENSOR NOT

GAIN

CALIBRATED

9915

Continuously

·Platform controls are prevented

·Platform Mode is prevented

Machine Setup’s PLATFORM

OPTION is ENABLED; UGM is fitted

with Fredericks tilt elements; Tilt

Gains in the Manufacturing Data
Area (0x4040 to 0x4046) are not

within 178-308

Power cycled

GROUND

MODULE

FAILURE –
HIGH SIDE

DRIVER

CUTOUT

FAULTY

9921

5000mS

Hydraulic functions are prevented

Machine Setup’s PLATFORM

OPTION is ENABLED;

Platform Mode is active; UGM

detects an issue with the High-Side

Driver Cutout circuitry associated
with UGM J2-1, J2-13, and J1-23

Power cycled

FUNCTIONS

LOCKED OUT –

MACHINE NOT

CONFIGURED

9924

5000mS

·Hydraulic functions are prevented

·Engine Start is prevented

·UGM J4-12 ECM / Fuel Relay is

energized to shutdown engine

Machine Setup’s MODEL is

UNKNOWN

Machine

Setup’s

MODEL is

set; Power

cycled

CURRENT

FEEDBACK

GAINS OUT OF

RANGE

9944

Continuously

·Hydraulic functions are prevented

·Engine Start is prevented

·UGM J4-12 ECM / Fuel Relay is

energized to shutdown engine

Current feedback calibration data in

the Manufacturing Data Area

(0x4050; J3-1, J3-2, J3-4, J3-5, J3-

6, J3-14) to are not within 204-307

Power cycled

CURRENT

FEEDBACK

CALIBRATION

CHECKSUM

INCORRECT

9945

Continuously

·Hydraulic functions are prevented

·Engine Start is prevented

·UGM J4-12 ECM / Fuel Relay is

energized to shutdown engine

Checksum for the current feedback

calibration data in the Manufacturing

Data Area (0x4050) was improper

Power cycled

CABIN

DISPLAY

EEPROM

WRITE

FAILURE

9946

5000mS

EEPROM access to the Cabin

Display for Hardware Exchange

functionality has failed

Power cycled

HARDWARE

EXCHANGE

REQUIRED

9947

5000mS

·Hydraulic functions are prevented

·Display “PERFORM HARDWARE

EXCHANGE” on Cabin Display

FUNCTIONS LOCKED OUT –

MACHINE NOT CONFIGURED

(9924) fault is not active; control

system detects a data mismatch

between the UGM and Cabin

Display EEPROM

HARDWARE

EXCHANGE

must be

completed

successfully;

Power cycled

Advertising
This manual is related to the following products: