Electrical system – JLG 4017PS Service Manual User Manual

Page 217

Advertising
background image

9-59

3706PS, 3707PS, 4014PS, 4017PS, 33.7, 37.6, 37.7

Electrical System

CABIN JOYSTICK –

FNR SWITCH

FAULT

23115

Continuously

Direction Selection shall be

Neutral

Cabin joystick transmits Error (1:0)

for the Forward, Neutral, or Reverse

switches

Cabin joystick transmits Switch

Closed (0:1) for more than one

position (Forward, Neutral, Reverse)

for 500mS

Cabin joystick transmit Switch Open

(0:0) for all position (Forward,

Neutral, Reverse) for 500mS

Power cycled

BOOM ANGLE

SENSOR –

INTERNAL

FAILURE

2353

Continuously

Boom angle sensor reading is

+99°

Lift Up is de-rated to 60%

(Constant Data) of the maximum

personality for Cabin Mode

Lift Up is prevented if the platform

is attached in Cabin Mode

All functions are prevented in

Platform Mode

Hydraulic Quick Connect is

prevented

Machine Setup’s PLATFORM

OPTION is ENABLED; the primary

and backup sensor readings

disagree by more than 7 counts

(2.5°) for 1,000mS

Machine Setup’s PLATFORM

OPTION is ENABLED; the primary

or backup sensor reading was

greater than 250 counts (out of

range)

Power cycled

OPERATING

INTERLOCK –

ATTACHMENT

COUPLING PIN

NOT ENGAGED

2354

5000mS

Main Lift Up, Lift Down, Telescope

In, and Telescope Out function

speeds are reduced (same as

chassis is tilted) when the engine

is running in Cabin Mode

Transition from Cabin to Platform

Mode is prevented

Main Lift Up, Lift Down, Telescope

In, and Telescope Out function

speeds are reduced (same as

chassis is tilted) when the engine

is running in Platform Mode after

power-up

Machine Setup’s PLATFORM

OPTION is ENABLED;

the platform is attached; the

hydraulic coupling pin not engaged

(PLT J1-1 digital input low)

Hydraulic

coupling pin is

engaged for

at least

3,000mS

OPERATING

INTERLOCK –

PLATFORM NOT

COUPLED

2384

5000mS

Engine Start is prevented

Machine Setup’s PLATFORM

OPTION is ENABLED; Machine

Setup’s MARKET is AUSTRALIA;

Key switch Platform; platform is

attached; platform is not coupled

Platform is

coupled for at

least

2,000mS

ERRATIC

PLATFORM

COUPLED SIGNAL

2385

5000mS

Assume that platform is coupled

Machine Setup’s PLATFORM

OPTION is ENABLED; Machine

Setup’s MARKET is AUSTRALIA;

UGM detects three signal transitions
on the platform coupled signal within

5,000mS

Power cycled

LOSS OF

PLATFORM

COUPLED SIGNAL

2386

5000mS

Machine Setup’s PLATFORM

OPTION is ENABLED; Machine

Setup’s MARKET is AUSTRALIA;

Key switch Cabin; platform is

attached; platform is not coupled

Power cycled

FAN REVERSE

DEMAND SWITCH

– PERMANENTLY

SELECTED

23118

5000mS

Fan Reversing is prevented

Hydraulic Variable Speed Fan or

Reversing Fan is configured; Fan

Reverse Demand Switch is closed

at power-up or more than 10,000mS

Power cycled

Advertising