Electrical system – JLG 4017PS Service Manual User Manual

Page 222

Advertising
background image

Electrical System

9-64

3706PS, 3707PS, 4014PS, 4017PS, 33.7, 37.6, 37.7

HYDRAULIC

QUICK CONNECT

SELECT – SHORT

TO BATTERY

33205

Continuously

Auxiliary Function-A is prevented

Auxiliary Function-B is prevented

UGM J3-14 Aux Return is disabled

Continuous Auxiliary Hydraulics is

prevented

Hydraulic Quick Connect is

prevented

Auxiliary Release is prevented

Machine Setup’s HYDRAULIC

QUICK CONNECT is YES; short to

battery is detected on UGM J1-23

Power cycled

HYDRAULIC

QUICK CONNECT

SELECT – SHORT

TO GROUND

33206

Continuously

Auxiliary Function-A is prevented

Auxiliary Function-B is prevented

UGM J3-14 Aux Return is disabled

Continuous Auxiliary Hydraulics is

prevented

Hydraulic Quick Connect is

prevented

Auxiliary Release is prevented

Machine Setup’s HYDRAULIC

QUICK CONNECT is YES; short to

battery is detected on UGM J1-23

Power cycled

HORN – OPEN

CIRCUIT

33207

5000mS

Horn digital output is prevented

Platform attached; open-circuit is

detected on UGM J2-2

Power cycled

HORN – SHORT

TO BATTERY

33208

5000mS

Horn digital output is prevented

Platform attached; short to battery

is detected on UGM J2-2

Power cycled

HORN – SHORT

TO GROUND

33209

5000mS

Horn digital output is prevented

Platform attached; short to ground

is detected on UGM J2-2

Power cycled

DUMP VALVE –

OPEN CIRCUIT

33213

Continuously

Dump Valve digital output is

prevented

Machine Setup’s PLATFORM

OPTION is ENABLED; Cabin

Mode; open-circuit is detected on

UGM J2-13

Machine Setup’s PLATFORM

OPTION is ENABLED; Platform

Mode; 1,000mS after Platform
startup sequence is complete;

open-circuit is detected on UGM

J2-13

Power cycled

DUMP VALVE –

SHORT TO

BATTERY

33214

Continuously

Hydraulic functions are prevented

Dump Valve digital output is

prevented

Machine Setup’s PLATFORM

OPTION is ENABLED; short to

battery is detected on UGM J2-13

Power cycled

DUMP VALVE –

SHORT TO

GROUND

33215

Continuously

Dump Valve digital output is

prevented

Machine Setup’s PLATFORM

OPTION is ENABLED; Cabin

Mode; short to ground is detected

on UGM J2-13

Machine Setup’s PLATFORM

OPTION is ENABLED; Platform

Mode; PLT J2-19 digital output is

energized; short to ground is

detected on UGM J2-13

Power cycled

AUXILIARY
FUNCTION

SELECT – OPEN

CIRCUIT

33216

5000mS

Continuous Auxiliary Hydraulics is

prevented

Hydraulic Quick Connect is

prevented

Auxiliary Release is prevented

Machine Setup’s AUXILIARY
FUNCTION SELECT is YES;

Cabin Mode is selected; open-

circuit is detected on UGM J2-1

Power cycled