JLG 4017PS Service Manual User Manual

Page 259

Advertising
background image

9-101

3706PS, 3707PS, 4014PS, 4017PS, 33.7, 37.6, 37.7

Electrical System

1335

524000

4

8-0-0

High side to low side short circuit in the injector 7 (in firing order)

1336

524001

4

8-0-1

High side to low side short circuit in the injector 8 (in firing order)

1337

2797

4

Injector diagnostics; time out error of short circuit to ground
measurement cyl. Bank 0

1338

2798

4

Injector diagnostics; time out error of short circuit to ground
measurement cyl. Bank 1

1339

2798

4

Injector diagnostics; short circuit to ground monitoring Test in Cyl.
Bank 0

1340

2798

4

Injector diagnostics; short circuit to ground monitoring Test in Cyl.
Bank 1

1341

524035

12

5-5-5

Injector diagnostics; time out error in the SPI communication

1342

524036

12

Injector diagnostics Slave; time out error in the SPI communication

1343

524004

12

8-0-4

Too many recognized misfires in cylinder 7 (in firing order)

1344

524005

12

8-0-5

Too many recognized misfires in cylinder 8 (in firing order)

1345

524069

9

Time out Error of CAN-Receive-Frame MSMon_FidFCCTO;
Master-Slave CAN communication faulty

1357

524052

11

Error memory Slave reports FID MSMonFC2; Shut-Off Path test
error of fuel injection system

1368

524052

11

Error memory Slave reports FID MSMonFC3; time out of engine
state messages (ComMS_Sys1-7) from master ECU

1378

523919

2

6-9-4

Sensor air pump air pressure; plausibility error

1379

523920

2

7-1-6

Sensor exhaust gas back pressure burner; plausibility error

1380

3253

2

6-9-2

Sensor differential pressure (DPF); plausibility error

1381

164

2

8-3-9

Rail pressure safety function is not executed correctly

1389

523922

5

7-1-5

Burner Shut Off Valve; open load

1390

523922

12

7-1-5

Burner Shut Off Valve; powerstage over temperature

1392

523922

4

7-1-5

Burner Shut Off Valve; short circuit to ground

1395

523921

2

7-1-4

Sensor burner temperature; plausibility error

1398

1136

0

6-8-1

Physical range check high for ECU temperature

1399

1136

1

6-8-1

Physical range check low for ECU temperature

1400

1136

3

6-8-1

Sensor error ECU temperature; signal range check high

Advertising