9-57

3706PS, 3707PS, 4014PS, 4017PS, 33.7, 37.6, 37.7

Electrical System

BOOM ANGLE

SENSOR – NOT

CALIBRATED

2343

5000mS

Boom angle sensor reading is

+99°

Lift Up is de-rated to 60%

(Constant Data)

of the maximum personality for

Cabin Mode

Lift Up is de-rated to 20%

(Constant Data) of the maximum

personality for Platform Mode

Hydraulic Quick Connect is

allowed despite boom angle

(DFM)

Platform controls shall be

prevented

The UGM detects that a valid boom

angle sensor calibration has not

been performed

The Boom

Angle Sensor

Calibration

procedure is

performed

successfully

BOOM ANGLE

SENSOR – OUT OF

RANGE HIGH

2344

5000mS

Boom angle sensor reading is

+99°

Lift Up is de-rated to 60%

(Constant Data)

of the maximum personality for

Cabin Mode

Lift Up is de-rated to 20%

(Constant Data) of the maximum

personality for Platform Mode

Machine Setup’s PLATFORM

OPTION is DISABLED; UGM J7-4

Boom Angle Sensor analog input is

more than 4.5V

Power cycled

BOOM ANGLE

SENSOR – OUT OF

RANGE LOW

2345

5000mS

Boom angle sensor reading is

+99°

Lift Up is de-rated to 60%

(Constant Data)

of the maximum personality for

Cabin Mode

Lift Up is de-rated to 20%

(Constant Data) of the maximum

personality for Platform Mode

Machine Setup’s PLATFORM

OPTION is DISABLED; UGM J7-4

Boom Angle Sensor analog input is

less than 0.6V

Power cycled

BOOM ANGLE

SENSOR – NOT

RESPONDING

2346

5000mS

Boom angle sensor reading is

+99°

Lift Up is de-rated to 60%

(Constant Data)

of the maximum personality for

Cabin Mode

Lift Up is prevented if the platform

is attached in Cabin Mode

All functions are prevented in

Platform Mode

Main Lift Up or Down valve current

greater than 950mA;

the engine is running; BOOM

ANGLE SENSOR – NOT

CALIBRATED (2342) not active;

BOOM ANGLE SENSOR – OUT OF

RANGE HIGH (2344) not active;

BOOM ANGLE SENSOR – OUT OF

RANGE LOW (2345) not active;

LIFT – CURRENT FEEDBACK

READING TOO LOW (33287) not

active; boom not within +3.0° of

mechanical stop; boom angle >

+10° (for bucket tear out capability);

boom angle sensor does not change

at least 0.5° in 4,000mS; DEBUG à

BOOM NR is NO

Power cycled