Electrical system – JLG 4017PS Service Manual User Manual

Page 231

Advertising
background image

9-73

3706PS, 3707PS, 4014PS, 4017PS, 33.7, 37.6, 37.7

Electrical System

h. Communications (66X)

COMMUNICATIONS

66XXX

-

-

-

-

CANBUS FAILURE –

PLATFORM MODULE

662

Continuously

All platform controls are

prevented

Machine Setup’s PLATFORM

OPTION is ENABLED;

Keyswitch Platform; Platform

Module messages not detected for

more than 250mS

Power cycled

CANBUS FAILURE –

LOAD SENSING

SYSTEM MODULE

663

Continuously

Platform assumed to be

overloaded

Machine Setup’s PLATFORM

OPTION is ENABLED; Load

Sensing System is configured;

platform attached; keyswitch

platform; LSS Module messages not

detected for more than 1,000mS

Power cycled

CANBUS FAILURE –

ENGINE CONTROLLER

666

Continuously

·Engine Start is prevented

·Hydraulic Variable Speed

Fan shall operate at maximum

speed

Electronic Engine is configured;

ECM messages not detected >

1000mS;

UGM J4-12 is de-energized (Anti-

Theft Disabled)

Power cycled

CANBUS FAILURE –

EXCESSIVE CANBUS

ERRORS

6613

Continuously

UGM detects > 500 Bus-Off

conditions during a power cycle or

> 22 Bus-Off conditions in 1,000mS

Power cycled

CANBUS FAILURE –

TRANSMISSION

CONTROLLER

6616

Continuously

·Direction Selection shall be

Neutral

·FWD LOW, FWD HIGH,

REVERSE, 1ST GEAR, 2ND

GEAR, and 3RD GEAR

Transmission Solenoid are

prevented

TCM messages not detected >

1,000mS;

SA is 0x04 when TCMSELECT is

ICA & 0x03 otherwise;

engine is not cranking

Power cycled

CANBUS FAILURE –

CABIN JOYSTICK

6617

Continuously

Hydraulic functions are

prevented

Cabin Mode is active; engine is not

cranking;

Cabin Joystick messages not

detected for at least 1,000mS

Cabin

Joystick

messages

detected

CANBUS FAILURE –

CABIN DISPLAY

6618

Continuously

Cabin Display messages not

detected > 500mS

Power cycled

CANBUS FAILURE –

BOOM ANGLE

SENSOR

6621

Continuously

·Boom angle sensor assumed

to be +99°

·Lift Up is prevented in

Platform Mode, when the

platform is attached, or when

the platform is coupled

·Lift Up and Down is de-rated

to 60% (Constant Data) for

Cabin Mode

Machine Setup’s PLATFORM

OPTION is ENABLED; Boom Angle

Sensor messages not detected >

250mS

Power cycled

CANBUS FAILURE –

TCU MODULE

6622

-

Machine Setup’s CLEARSKY is

YES;

TCU messages not detected > 30

seconds

TCU

messages

detected

CANBUS FAILURE –
GATEWAY MODULE

6623

-

Machine Setup’s CLEARSKY is

YES;

Gateway messages not detected >

30 seconds

Gateway

messages

detected

Advertising