Electrical system – JLG 4017PS Service Manual User Manual

Page 224

Advertising
background image

Electrical System

9-66

3706PS, 3707PS, 4014PS, 4017PS, 33.7, 37.6, 37.7

RIGHT

STABILIZER UP

VALVE – OPEN

CIRCUIT

33231

5000mS

Stabilizers are prevented

Machine Setup’s MODEL is 4014

or 4017; open circuit is detected on

UGM J2-3

Power cycled

RIGHT

STABILIZER UP

VALVE – SHORT

TO BATTERY

33232

Continuously

Stabilizers are prevented

Frame Level is prevented

Machine Setup’s MODEL is 4014

or 4017; short to battery is

detected on UGM J2-3

Power cycled

RIGHT

STABILIZER UP

VALVE – SHORT

TO GROUND

33233

5000mS

Stabilizers are prevented

Machine Setup’s MODEL is 4014

or 4017; short to ground is

detected on UGM J2-3

Power cycled

FRAME LEVEL

LEFT VALVE –

OPEN CIRCUIT

33234

5000mS

Frame Level Left is prevented

Machine Setup’s MODEL is 4014

or 4017; open circuit is detected on

UGM J2-7

Power cycled

FRAME LEVEL

LEFT VALVE –

SHORT TO

BATTERY

33235

Continuously

Stabilizers are prevented

Frame Level is prevented

Machine Setup’s MODEL is 4014

or 4017; short to battery is

detected on UGM J2-7

Power cycled

FRAME LEVEL

LEFT VALVE –

SHORT TO

GROUND

33236

5000mS

Frame Level Left is prevented

Machine Setup’s MODEL is 4014

or 4017; short to ground is

detected on UGM J2-7

Power cycled

FRAME LEVEL

RIGHT VALVE –

OPEN CIRCUIT

33237

5000mS

Frame Level Right is prevented

Machine Setup’s MODEL is 4014

or 4017; open circuit is detected on

UGM J2-5

Power cycled

FRAME LEVEL

RIGHT VALVE –

SHORT TO

BATTERY

33238

Continuously

Stabilizers are prevented

Frame Level is prevented

Machine Setup’s MODEL is 4014

or 4017; short to battery is

detected on UGM J2-5

Power cycled

FRAME LEVEL

RIGHT VALVE –

SHORT TO

GROUND

33239

5000mS

Frame Level Right is prevented

Machine Setup’s MODEL is 4014

or 4017; short to ground is

detected on UGM J2-5

Power cycled

CRAB STEER

VALVE – OPEN

CIRCUIT

33270

5000mS

Open-circuit is detected on UGM

J2-16

Power cycled

CRAB STEER

VALVE – SHORT

TO BATTERY

33271

5000mS

Short to battery is detected on

UGM J2-16

Power cycled

CRAB STEER

VALVE – SHORT

TO GROUND

33272

5000mS

Short to ground is detected on

UGM J2-16

Power cycled

ALL WHEEL

STEER VALVE –

OPEN CIRCUIT

33273

5000mS

Open-circuit is detected on UGM

J2-4

Power cycled

ALL WHEEL

STEER VALVE –

SHORT TO

BATTERY

33274

5000mS

Short to battery is detected on

UGM J2-4

Power cycled

Advertising