Electrical system – JLG 4017PS Service Manual User Manual

Page 230

Advertising
background image

Electrical System

9-72

3706PS, 3707PS, 4014PS, 4017PS, 33.7, 37.6, 37.7

TRANSMISSION

FWD HIGH COIL –

SHORT TO

BATTERY OR

OPEN CIRCUIT

4632

Continuously

Direction Selection shall be Neutral

when Calibration’s TRANS

SERVICE is NO

Short to battery or open-circuit is

detected on TCM J5-4 for

1,000mS

Power cycled

TRANSMISSION

FWD HIGH COIL –

SHORT TO

GROUND

4633

Continuously

Direction Selection shall be Neutral

when Calibration’s TRANS

SERVICE is NO

Short to ground is detected on

TCM J5-4

Power cycled

TRANSMISSION

1ST GEAR COIL –

SHORT TO

BATTERY OR

OPEN CIRCUIT

4634

Continuously

Direction Selection shall be Neutral

when Calibration’s TRANS

SERVICE is NO

Short to battery or open-circuit is

detected on TCM J5-6 for

1,000mS

Power cycled

TRANSMISSION

1ST GEAR COIL –

SHORT TO

GROUND

4635

Continuously

Direction Selection shall be Neutral

when Calibration’s TRANS

SERVICE is NO

Short to ground is detected on

TCM J5-6

Power cycled

TRANSMISSION

2ND GEAR COIL –

SHORT TO

BATTERY OR

OPEN CIRCUIT

4636

Continuously

Direction Selection shall be Neutral

when Calibration’s TRANS

SERVICE is NO

Short to battery or open-circuit is

detected on TCM J5-7 for

1,000mS

Power cycled

TRANSMISSION

2ND GEAR COIL –

SHORT TO

GROUND

4637

Continuously

Direction Selection shall be Neutral

when Calibration’s TRANS

SERVICE is NO

Short to ground is detected on

TCM J5-7

Power cycled

TRANSMISSION

3RD GEAR COIL –

SHORT TO

BATTERY OR

OPEN CIRCUIT

4638

Continuously

Direction Selection shall be Neutral

when Calibration’s TRANS

SERVICE is NO

Short to battery or open-circuit is

detected on TCM J5-8 for

1,000mS

Power cycled

TRANSMISSION

3RD GEAR COIL –

SHORT TO

GROUND

4639

Continuously

Direction Selection shall be Neutral

when Calibration’s TRANS

SERVICE is NO

Short to ground is detected on

TCM J5-8

Power cycled

HYD FLUID TEMP

SENSOR –

SHORT TO

BATTERY OR

OPEN CIRCUIT

4640

5000mS

Hydraulic Variable Speed operates
at maximum speed

Hydraulic Variable Speed Fan is

configured;

TCM J3-5 is greater than 4.5V

Power cycled

TRANS FLUID

TEMP SENSOR –

SHORT TO

BATTERY OR

OPEN CIRCUIT

4641

5000mS

Hydraulic Variable Speed operates
at maximum speed

Hydraulic Variable Speed Fan is

configured;

TCM J3-8 is greater than 4.5V

Power cycled

INTERCOOLER

AIR TEMP

SENSOR –

SHORT TO

BATTERY OR

OPEN CIRCUIT

4642

5000mS

Hydraulic Variable Speed operates
at maximum speed

Hydraulic Variable Speed Fan is
configured; ENGINE CONTROL

is TCD3.6L 90.0kW or TCD3.6L

74.4kW;

TCM J3-11 is greater than 4.5V

Power cycled