Electrical System

9-60

3706PS, 3707PS, 4014PS, 4017PS, 33.7, 37.6, 37.7

c. Function Prevented (25X)

OPERATING MODE

INTERLOCK –

OPERATOR

PRESENCE

23120

Continuously

Cabin Mode; Machine Setup’s

OPERATOR PRESENCE is YES;

and operator is not present

Operator is

present

FUNCTION

PREVENTED

25XXX

-

-

-

-

MODEL CHANGED

– HYDRAULICS

SUSPENDED –

CYCLE EMS

259

Continuously

Hydraulic functions are prevented

Engine Start is prevented

Machine Setup’s MODEL was

changed

Power cycle

FUNCTIONS

LOCKED OUT –

CONSTANT DATA

VERSION

IMPROPER

2520

Continuously

Hydraulic functions are prevented

Engine Start is prevented

UGM Constant Data version does

not agree with Application

Re-program

UGM; Power

cycled

ENGINE START

PREVENTED –

PARK BRAKE NOT

SET

2525

5000mS

Engine Start is prevented

UGM J4-8 Engine Start digital input

is high (key in start position) and

UGM J4-5 Park Brake is low (not

set).

UGM J4-5

Park Brake is

high (set;

250mS).

BOOM EXTENDED

SWITCH –

CONFLICTING

STATE

2526

5000mS

Machine Setup’s MODEL is 4014;

PLATFORM OPTION is

ENABLED;

UGM J7-8 Boom Extension Switch

indicates critical (de-energized);

UGM J3-8 Boom Retracted Switch

indicates retracted (energized)

Power cycle

EXCESSIVE BOOM

ANGLE FOR
HYDRAULIC

QUICK CONNECT

OPERATION

2527

5000mS

Hydraulic Quick Connect is

prevented

Machine Setup’s HYDRAULIC

QUICK CONNECT is YES;

boom angle is greater than +20°;

Hydraulic Quick Connect Switch is

pressed

Hydraulic

Quick

Connect

Switch is

released;

boom angle is

reduced

PLATFORM

ATTACHED –

HYDRAULIC

QUICK CONNECT

CUTOUT

2528

5000mS

Hydraulic Quick Connect is

prevented

Machine Setup’s HYDRAULIC

QUICK CONNECT is YES; Cabin

Mode; platform is attached;

Hydraulic Quick Connect Switch is

pressed

Hydraulic

Quick

Connect

Switch is

released;

disconnect

platform

cable before

using

hydraulic

quick connect
to release the

attachment

ENGINE START

PREVENTED –

SHIFT LEVER NOT

IN NEUTRAL

2529

5000mS

Engine Start is prevented

Cabin Mode; UGM J4-8 Engine

Start digital input is energized;

the cabin joystick’s FNR switch is

set to forward or reverse

Cabin

joystick’s

FNR switch is

set to neutral

Advertising