Electrical system – JLG 4017PS Service Manual User Manual

Page 223

Advertising
background image

9-65

3706PS, 3707PS, 4014PS, 4017PS, 33.7, 37.6, 37.7

Electrical System

AUXILIARY
FUNCTION

SELECT – SHORT

TO BATTERY

33217

Continuously

Auxiliary Function-A is prevented

Auxiliary Function-B is prevented

UGM J3-14 Aux Return is disabled

Continuous Auxiliary Hydraulics is

prevented

Hydraulic Quick Connect is

prevented

Auxiliary Release is prevented

Machine Setup’s AUXILIARY
FUNCTION SELECT is YES;

Cabin Mode is selected; short to

battery is detected on UGM J2-1

Power cycled

AUXILIARY
FUNCTION

SELECT – SHORT

TO GROUND

33218

Continuously

Auxiliary Function-A is prevented

Auxiliary Function-B is prevented

UGM J3-14 Aux Return is disabled

Continuous Auxiliary Hydraulics is

prevented

Hydraulic Quick Connect is

prevented

Auxiliary Release is prevented

Machine Setup’s AUXILIARY
FUNCTION SELECT is YES;

Cabin Mode is selected; short to

ground is detected on UGM J2-1

Power cycled

LEFT STABILIZER

DOWN VALVE –

OPEN CIRCUIT

33222

5000mS

Left & Right Stabilizer Down is

prevented

Machine Setup’s MODEL is 4014

or 4017; open circuit is detected on

UGM J2-21

Power cycled

LEFT STABILIZER

DOWN VALVE –

SHORT TO

BATTERY

33223

Continuously

Stabilizers are prevented

Frame Level is prevented

Machine Setup’s MODEL is 4014

or 4017; short to battery is

detected on UGM J2-21

Power cycled

LEFT STABILIZER

DOWN VALVE –

SHORT TO

GROUND

33224

5000mS

Left & Right Stabilizer Down is

prevented

Machine Setup’s MODEL is 4014

or 4017; short to ground is

detected on UGM J2-21

Power cycled

LEFT STABILIZER

UP VALVE – OPEN

CIRCUIT

33225

5000mS

Stabilizers are prevented

Machine Setup’s MODEL is 4014

or 4017; open circuit is detected on

UGM J2-10

Power cycled

LEFT STABILIZER

UP VALVE –

SHORT TO

BATTERY

33226

Continuously

Stabilizers are prevented

Frame Level is prevented

Machine Setup’s MODEL is 4014

or 4017; short to battery is

detected on UGM J2-10

Power cycled

LEFT STABILIZER

UP VALVE –

SHORT TO

GROUND

33227

5000mS

Stabilizers are prevented

Machine Setup’s MODEL is 4014

or 4017; short to ground is

detected on UGM J2-10

Power cycled

RIGHT

STABILIZER

DOWN VALVE –

OPEN CIRCUIT

33228

5000mS

Left & Right Stabilizer Down is

prevented

Machine Setup’s MODEL is 4014

or 4017; open circuit is detected on

UGM J2-15

Power cycled

RIGHT

STABILIZER

DOWN VALVE –

SHORT TO

BATTERY

33229

Continuously

Stabilizers are prevented

Frame Level is prevented

Machine Setup’s MODEL is 4014

or 4017; short to battery is

detected on UGM J2-15

Power cycled

RIGHT

STABILIZER

DOWN VALVE –

SHORT TO

GROUND

33230

5000mS

Left & Right Stabilizer Down is

prevented

Machine Setup’s MODEL is 4014

or 4017; short to ground is

detected on UGM J2-15

Power cycled

Advertising